2014
DOI: 10.1016/j.radmeas.2014.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Basic characteristics of tissue-equivalent phantom thermoluminescence slab dosimeter using new TL phosphor Li3B7012:Cu

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…To prevent the synthetic resin from softening in heat, the TLDs were heated with a temperature limit of 180°C. The density and the effective atomic number were 1.01 g cm −3 and 7.42, respectively [6]. In this report, TL phosphor Li 3 B 7 O 12 :Cu with a size of 10 mm × 10 mm × 2.5 mm was used.…”
Section: Tl Phosphor LI 3 B 7 O 12 :Cu and Glow Curve Readout Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…To prevent the synthetic resin from softening in heat, the TLDs were heated with a temperature limit of 180°C. The density and the effective atomic number were 1.01 g cm −3 and 7.42, respectively [6]. In this report, TL phosphor Li 3 B 7 O 12 :Cu with a size of 10 mm × 10 mm × 2.5 mm was used.…”
Section: Tl Phosphor LI 3 B 7 O 12 :Cu and Glow Curve Readout Systemmentioning
confidence: 99%
“…Recently, a tissue equivalent slab-type TLD based on the phosphor Li 3 B 7 O 12 :Cu has been developed to verify the dose distribution in 3D [6]. The tissue equivalent slab-type TLD has shown good dose linearity and excellent spatial resolution, so that it has the potential to be a 3D dose verification tool [6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several 2D thermoluminescence dosimeters (TLDs) have been developed since the 1960s and are expected to be applied as reusable 2D passive dosimeters with a wide dynamic range. (6)(7)(8)(9)(10)(11)(12) In particular, tissue-equivalent 2D TLDs have been developed and used for clinical applications because of their small energy dependence. 2D TLDs have a potential advantage in being capable of correcting sensitivity nonuniformities for every pixel of acquired thermoluminescence (TL) images owing to their repeatability.…”
Section: Introductionmentioning
confidence: 99%
“…The repeatability obtained using a photomultiplier tube (PMT) system is well within 1% of the coefficient of variation (CV), and the dose response linearity ranges up to approximately 5 Gy for 6 MV X-ray beams. (12) The TL properties for charged particles have also been reported. (15,16) In addition, the use of water as a phantom material is standard for reference dosimetry in radiotherapy, and Al 2 O 3 :Cr TLDs can be used under water.…”
Section: Introductionmentioning
confidence: 99%