2012
DOI: 10.1063/1.3669756
|View full text |Cite
|
Sign up to set email alerts
|

Beam emission spectroscopy turbulence imaging system for the MAST spherical tokamak

Abstract: A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D(α) emission from the ~2 MW heating beam of ~70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 × 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit dig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
56
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 30 publications
(56 citation statements)
references
References 16 publications
0
56
0
Order By: Relevance
“…Beam Emission Spectroscopy (BES) measurements of density fluctuations in tokamak plasmas [17][18][19][20][21] have made it possible to probe ion-scale turbulence in these devices directly. In this Letter, we use such measurements in the MAST tokamak, along with the local equilibrium parameters calculated by other diagnostics, to estimate and compare the characteristic time scales of the turbulent fluctuations in the energy-containing range.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Beam Emission Spectroscopy (BES) measurements of density fluctuations in tokamak plasmas [17][18][19][20][21] have made it possible to probe ion-scale turbulence in these devices directly. In this Letter, we use such measurements in the MAST tokamak, along with the local equilibrium parameters calculated by other diagnostics, to estimate and compare the characteristic time scales of the turbulent fluctuations in the energy-containing range.…”
mentioning
confidence: 99%
“…During the 2011 campaign, density fluctuation data from the BES diagnostic [21] on MAST were collected in a variety of discharges (including L-and H-modes and internal transport barriers). Here we report the data from 39 neutral- beam heated "double-null-diverted" discharges, with no pellet injection and no resonant magnetic perturbations.…”
mentioning
confidence: 99%
“…Aligning the LoS parallel to the local magnetic field at the intersection of the LoS and the neutral heating beam helps minimize the degradation of the spatial resolution. A more detailed description of the 2D BES system on MAST with possible sources of some losses of spatial locality can be found elsewhere [16,20].…”
Section: What Is Measured By the 2d Bes Systemmentioning
confidence: 99%
“…where I ij DC is the DC value -a typical value of 0.8 V is used for all channels [16]. The rest of the terms are as follows.…”
Section: Appendix A2 Synthetic 2d Bes Datamentioning
confidence: 99%
See 1 more Smart Citation