2017
DOI: 10.1002/acm2.12147
|View full text |Cite
|
Sign up to set email alerts
|

Beam focal spot position: The forgotten linac QA parameter. An EPID‐based phantomless method for routine Stereotactic linac QA

Abstract: Modern day Stereotactic treatments require high geometric accuracy of the delivered treatment. To achieve the required accuracy the IGRT imaging isocenter needs to closely coincide with the treatment beam isocenter. An influence on this isocenter coincidence and on the spatial positioning of the beam itself is the alignment of the treatment beam focal spot with collimator rotation axis. The positioning of the focal spot is dependent on the linac beam steering and on the stability of the monitor chamber and bea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(18 citation statements)
references
References 8 publications
0
18
0
Order By: Relevance
“…It was noticed that the mean discrepancy in validating beam focal spot offsets against the ionization chamber method was four times higher on Elekta linacs with the Agility ® head (0.004 ± 0.052 mm) compared to published results for Varian linacs (0.001 ± 0.015 mm). No specific reason for this was found other than the fact that the reproducibility of beam focal spot position is substantially higher on the Elekta machines.…”
Section: Resultsmentioning
confidence: 77%
See 3 more Smart Citations
“…It was noticed that the mean discrepancy in validating beam focal spot offsets against the ionization chamber method was four times higher on Elekta linacs with the Agility ® head (0.004 ± 0.052 mm) compared to published results for Varian linacs (0.001 ± 0.015 mm). No specific reason for this was found other than the fact that the reproducibility of beam focal spot position is substantially higher on the Elekta machines.…”
Section: Resultsmentioning
confidence: 77%
“…An innovative phantom‐less method of measuring beam focal spot offset using the EPID has been presented for Elekta linacs with the Agility ® head. It is a modification of the method described previously for Varian linacs, which have two sets of jaws as opposed to one for the Agility ® head. It has the same advantages of being an accurate, practical and fast technique.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The source displacement was relative to the source position in the first test execution. It was introduced by modifying the source position on the target using the linac beam steering and adjusting the beam steering servos, and the amplitude of the source displacement was measured with the independent verification method presented in Chojnowski et al, but with a manually positionned ionisation chamber. Table presents the averages of errors detected at each gantry angle.…”
Section: Resultsmentioning
confidence: 99%