2018
DOI: 10.1016/j.hrthm.2017.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Beat-to-beat variations in activation-recovery interval derived from the right ventricular electrogram can monitor arrhythmic risk under anesthetic and awake conditions in the canine chronic atrioventricular block model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 21 publications
0
20
0
Order By: Relevance
“…Wijers et al 16 Whilst strategies to analyze fractionated electrograms have been proposed, 33 a clear consensus in their interpretation does not exist. In the context of the assessment of BVR this could prove a challenge.…”
Section: Clinical Implications and Future Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Wijers et al 16 Whilst strategies to analyze fractionated electrograms have been proposed, 33 a clear consensus in their interpretation does not exist. In the context of the assessment of BVR this could prove a challenge.…”
Section: Clinical Implications and Future Workmentioning
confidence: 99%
“…Recent animal studies have demonstrated significant increases in the BBV of ARI prior to the onset of Torsades de pointes and have highlighted its potential for integration into implantable cardiac devices to monitor arrhythmia risk. 16 In the present study, we have recorded left ventricular (LV) unipolar electrograms (UEGs), while pacing from the right ventricular (RV) lead to maintain a constant cycle length in patients with heart failure. From these electrograms we have calculated ARI variability (ARIV).…”
Section: Introductionmentioning
confidence: 99%
“…Despite the methodological differences, a similar correlation between STV ARI and STV MAPD was found with an r 2 of 0.71. Recently, Wijers et al (2018) observed a positive correlation between STV MAPD and STV ARI from the RV EGM. Yet, the correlation was less strong (r 2 = 0.41), possibly due to differences in sampling frequency between the MAP and EGM recording (1,000 Hz for the MAP and 250 Hz, resampled to 400 Hz, for the EGM).…”
Section: Different Methods Of Stv Ari Compared To Stv Mapdmentioning
confidence: 95%
“…Therefore, STV dynamics could provide important information about impending arrhythmic events. Since MAP-catheters are rarely used outside the experimental laboratory, recent interest shifted toward measurement of STV on the EGM of chronically implanted ICD-leads (Oosterhoff et al, 2010(Oosterhoff et al, , 2011Wijers et al, 2018). These leads have the advantage of recording EGMs 24/7 from a fixed position on the myocardium.…”
Section: Stv As a Marker Of Arrhythmic Riskmentioning
confidence: 99%
See 1 more Smart Citation