2021
DOI: 10.1016/j.jobe.2021.102166
|View full text |Cite
|
Sign up to set email alerts
|

Behavior and design of concrete-filled narrow rectangular steel tubular (CFNRST) stub columns under axial compression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 16 publications
1
3
0
Order By: Relevance
“…Columns with square cross-sections exhibited the greatest ductility, and the elongation of one of the cross-section sided has a negative effect on its ductility. Similar observations were presented in [ 39 ].…”
Section: Ductility Of Cfst Columns—state-of-the-artsupporting
confidence: 91%
“…Columns with square cross-sections exhibited the greatest ductility, and the elongation of one of the cross-section sided has a negative effect on its ductility. Similar observations were presented in [ 39 ].…”
Section: Ductility Of Cfst Columns—state-of-the-artsupporting
confidence: 91%
“…Therefore, the accuracy of the bearing capacity prediction model based on the Gaussian process regression algorithm in this paper is better than that of the traditional empirical formula. In order to verify that the proposed bearing capacity model can predict data outside the database, this article collected an additional 60 sets of data [71][72][73][74] as test sets to verify the accuracy of the formula. From the results in Figure 12, it can be seen that the data points calculated by the proposed calculation formula are concentrated within an error line of ±10%, with an accuracy of 93.73%.…”
Section: Discussionmentioning
confidence: 99%
“…Süleyman Ipek [29] developed an experimental and analytical study on CFST columns with different cross-sections to investigate their behavior against axial load; the study focused on the elliptical sections, and the study showed that three types of failure occurred in the elliptical section, shear failure, local buckling failure, and phenomena of the elephant foot buckling, which occurred nearly of the top and bottom of the CFST columns; finally, the study showed that the design codes formula of AISC and EC4 for (rectangular and circular) section were modified to be capable of expecting the axial load value for the elliptical section of the CFST columns. Lei Zhang [30] carried out an experimental study on CFST narrow rectangular columns to study their behavior under axial compressions loading. Twenty-four experimental specimens were tested to involve the behavior of CFST columns with a narrow rectangular section, The study showed that the local buckling failure of CFST occurred near the buckling ring, and the study demonstrated that when the ratios of D/B decreased, D/t increased the ductility index and the strength index improved remarkably; finally the study showed that more different codes have a good predictor to the safe design loads.…”
Section: Introductionmentioning
confidence: 99%