2010
DOI: 10.1016/j.nucengdes.2009.11.010
|View full text |Cite
|
Sign up to set email alerts
|

Benchmark database on the evolution of two-phase flows in a vertical pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(10 citation statements)
references
References 9 publications
(10 reference statements)
0
10
0
Order By: Relevance
“…After adiabatic air-water flows (Lucas et al, 2010) and flows with condensing steam bubbles a test series on evaporating flows caused by pressure relief was conducted at Variable Gas Injection test section (Lucas et al, 2011). It consists of a vertical pipe with an inner diameter of 195.3 mm and a length of about 8 m.…”
Section: Experimental Setup and Measuring Techniquementioning
confidence: 99%
“…After adiabatic air-water flows (Lucas et al, 2010) and flows with condensing steam bubbles a test series on evaporating flows caused by pressure relief was conducted at Variable Gas Injection test section (Lucas et al, 2011). It consists of a vertical pipe with an inner diameter of 195.3 mm and a length of about 8 m.…”
Section: Experimental Setup and Measuring Techniquementioning
confidence: 99%
“…Flow structure visualization studies [7] show a clear separation of bubble sizes. In reality, the bubble size distribution is polydisperse as evidenced by the experimental data [8], but since the bubble size distribution is largely bimodal, such flows are often successfully simplified by considering the flow to consist of a small and a large bubble group. Two bubble groups are the minimum number of size groups needed since the interfacial forces act quite different between the groups.…”
Section: Multifield Model Formulationmentioning
confidence: 99%
“…A partial validation of the CMFD model was performed to confirm the validity of the hydrodynamic simulations without chemistry [26]. Computational simulations of upward, co-current adiabatic air-water flow in a vertical pipe are compared to high-quality experimental data from the Transient twO Phase FLOW test facility (TOPFLOW) at the Institute of Safety Research at the Forschungszentrum DresdenRossendorf [8]. Two cases were selected from the TOPFLOW experiment database with two-phase flow in the churn-turbulent flow regime.…”
Section: Model Testing and Validationmentioning
confidence: 99%
“…Several investigations have shown the capability of these sensors to provide valuable data for different gas-liquid two-phase flows. Example are: bubble size and local gas volume fraction distribution in a rectangular bubble column by Krepper et al [4], data on the evolution of co-current air-water two phase flows by Lucas et al [2], experimental investigations of horizontal slug flows by Da Silva et al [10], and others. The data obtained by such measurements have been used extensively for CFD code development and validation.…”
Section: Introductionmentioning
confidence: 99%