2021
DOI: 10.1021/acs.inorgchem.1c01410
|View full text |Cite
|
Sign up to set email alerts
|

Benzimidazole- and Imidazole-Fused Selenazolium and Selenazinium Selenocyanates: Ionic Organoselenium Compounds with Efficient Peroxide Scavenging Activities

Abstract: Three new classes of ionic organoselenium compounds containing cationic benzimidazolium and imidazolium ring systems with selenocyanates as counterions are described. The cyclization of N,N′-disubstituted benzimidazolium and imidazolium bromides having N-(CH2)2-Br and N-(CH2)3-Br groups in the presence of potassium selenocyanate (KSeCN) led to formation of the corresponding selenazolium selenocyanates (21a, 21b, 22a, and 22b) and selenazinium selenocyanates (21c, 21d, 22c, and 22d). However, the open-chain sel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(25 citation statements)
references
References 53 publications
1
23
0
Order By: Relevance
“…Column chromatography was performed either with a glass column loaded with neutral alumina or using an automated flash chromatography system (CombiFlash NextGen100, Teledynet) with manually packed cartridges using neutral alumina. NMR spectra ( 1 H, 13 C and 77 Se) were recorded on Bruker (400 or 600 MHz) NMR spectrometers and the chemical shifts were cited with respect to TMS (Me 4 Si) as an internal standard ( 1 H and 13 C nuclei) and Ph 2 Se 2 as an external standard ( 77 Se nuclei). Mass spectrometric analysis was performed using an Agilent Q-TOF 6520 High Resolution Mass Spectrometer in ESI-positive mode analysis.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Column chromatography was performed either with a glass column loaded with neutral alumina or using an automated flash chromatography system (CombiFlash NextGen100, Teledynet) with manually packed cartridges using neutral alumina. NMR spectra ( 1 H, 13 C and 77 Se) were recorded on Bruker (400 or 600 MHz) NMR spectrometers and the chemical shifts were cited with respect to TMS (Me 4 Si) as an internal standard ( 1 H and 13 C nuclei) and Ph 2 Se 2 as an external standard ( 77 Se nuclei). Mass spectrometric analysis was performed using an Agilent Q-TOF 6520 High Resolution Mass Spectrometer in ESI-positive mode analysis.…”
Section: Methodsmentioning
confidence: 99%
“…Compounds 11a-5 and 9d were synthesized following our reported method. 13 The 1 H, 13 C and 77 Se NMR spectra of the synthesized compounds are included in the ESI † (Fig. S1-S80).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations