Better Cryo-EM Specimen Preparation: How to Deal with the Air–Water Interface?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 105 publications
0
10
0
Order By: Relevance
“…The ‘resolution revolution’ of cryogenic-electron microscopy (cryo-EM) marks a significant shift in the field of structural biology 1 . However, the continued growth of cryo-EM single particle analysis (SPA) structural biology faces an unexpected problem at the step of sample grid preparation — sample damage 14 1,5,6 . The standard method for cryo-EM SPA sample grid preparation is plunge freezing, where small volumes of sample are applied onto a pretreated cryo-EM grid, blotted, and rapidly plunge-frozen into a cryogen such as liquid ethane.…”
Section: Mainmentioning
confidence: 99%
See 1 more Smart Citation
“…The ‘resolution revolution’ of cryogenic-electron microscopy (cryo-EM) marks a significant shift in the field of structural biology 1 . However, the continued growth of cryo-EM single particle analysis (SPA) structural biology faces an unexpected problem at the step of sample grid preparation — sample damage 14 1,5,6 . The standard method for cryo-EM SPA sample grid preparation is plunge freezing, where small volumes of sample are applied onto a pretreated cryo-EM grid, blotted, and rapidly plunge-frozen into a cryogen such as liquid ethane.…”
Section: Mainmentioning
confidence: 99%
“…To mitigate the AWI problem, researchers have developed a variety of solutions. These include the addition of mild detergents to the sample 6 , the use of chemical crosslinking 3,13,14 , and adsorbing or tethering samples to surfaces to prevent sample contact with the AWI 12,1524 . More sophisticated advanced techniques involve rapidly freezing the sample before the proteins can diffuse to the AWIs 2527 .…”
Section: Mainmentioning
confidence: 99%
“…To address these issues, other groups have developed methods to prevent nucleosome-protein complexes from contacting the AWI [15][16][17][18][19][20][21] . However, these methods either require the use of sophisticated equipment and/or materials for grid preparation.…”
Section: Introductionmentioning
confidence: 99%
“…It has been shown through recent studies that during freezing, very often macromolecules can interact with the air-water interface (AWI). This interaction can cause the macromolecules to denature, dissociate, adapt preferential orientations, or avoid the holes completely and stick to the carbon support (D’Imprima et al, 2019; Drulyte et al, 2018; Kampjut et al, 2021; Liu & Wang, 2023; Noble, Dandey, et al, 2018; Noble, Wei, et al, 2018). Along with protein biochemistry, the propensity of macromolecules to adopt preferential orientations is perhaps a common rate-limiting step in high-resolution structure determination.…”
Section: Introductionmentioning
confidence: 99%