Bilateral breast MRI by use of dual-source parallel radiofrequency excitation and image-based shimming at 3 Tesla: improvement in homogeneity on fat-suppression imaging

Abstract: In this study, we aimed to compare fat-suppression homogeneity on breast MR imaging by using dual-source parallel radiofrequency excitation and image-based shimming (DS-IBS) with single-source radiofrequency excitation with volume shim (SS-Vol) at 3 Tesla. Twenty patients were included. Axial three-dimensional T1-weighted turbo-field-echo breast images with DS-IBS and SS-Vol were obtained. Fat suppression was scored with four grade points. The contrast of the pectoral muscle and the fat in each breast area was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 21 publications
0
4
1
Order By: Relevance
“…This has been implemented primarily for breast imaging where air–tissue transitions often result in poor fat suppression. For breast imaging, IB‐shimming helps to significantly improve image quality compared to standard shimming methods . In our study, IB‐shimming did not significantly improve image quality nor reduce B 0 variation compared to the standard shimming method.…”
Section: Discussioncontrasting
confidence: 60%
See 2 more Smart Citations
“…This has been implemented primarily for breast imaging where air–tissue transitions often result in poor fat suppression. For breast imaging, IB‐shimming helps to significantly improve image quality compared to standard shimming methods . In our study, IB‐shimming did not significantly improve image quality nor reduce B 0 variation compared to the standard shimming method.…”
Section: Discussioncontrasting
confidence: 60%
“…The IB‐shimming is a software package implemented by the vendor and is primarily used for improved shimming of the breasts. It requires a fast (30 sec) low‐resolution fast‐field echo sequence to calculate first‐ and second‐order shim settings that maximize the B 0 ‐homogeneity in a region of interest (ROI) that is segmented following the contours of the anatomy …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…43 This may be accomplished through advanced hardware such as multi-channel parallel transmission which enables B 1 + shimming. 44 For IR-based techniques, switching the inversion RF pulse to an adiabatic pulse which is insensitive to B 1 + inhomogeneity can be helpful. 23 Fat suppression in the presence of metallic implant…”
Section: Figure 11 Two-point Dixon Techniquementioning
confidence: 99%
“…[7][8][9] Alternatively, fat suppressed high-resolution gradient echo (GRE) T1-weighted imaging is used, and a homogenous magnetic field is beneficial for sufficient fat suppression. 10 We know that the magnetic metallic core in the RFID will lead to a more inhomogeneous magnetic field, with negative impact on image quality. The images demonstrating reduction of artifacts in the comment from professor Munhoz are only T2-weighted.…”
mentioning
confidence: 99%