Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Fiber optic localized surface plasmon resonance (LSPR) sensors have become an effective tool in refractive index (RI) detection for biomedical applications because of their high sensitivity. However, using conventional optical fiber has caused limitations in implanting the sensor in the body. This research presents the design and construction of a new type of polymer-based LSPR sensors to address this issue. Also, finite element method (FEM) is used to design the sensor and test it theoretically. The proposed polymer optical fiber (POF) based on citrate is biocompatible, flexible, and degradable, with a rate of 22% and 27 over 12 days. The step RI structure utilizes two polymers for light transmission: poly (octamethylene maleate citrate) (POMC) as the core and poly (octamethylene citrate) (POC) as the cladding. The POF core and cladding diameters and lengths are 700 µm, 1400 µm, and 7 cm, respectively. The coupling efficiency of light to the POF was enhanced using a microsphere fiber optic tip. The obtained results show that the light coupling efficiency increased to 77.8%. Plasma surface treatment was used to immobilize gold nanoparticles (AuNPs) on the tip of the POF, as a LSPR-POF sensor. Adsorption kinetics was measured based on the pseudo-first-order model to determine the efficiency of immobilizing AuNPs, in which the adsorption rate constant (k) was obtained be 8.6 × 10–3 min−1. The RI sensitivity of the sensor in the range from 1.3332 to 1.3604 RIU was obtained as 7778%/RIU, and the sensitivity was enhanced ~ 5 times to the previous RI POF sensors. These results are in good agreement with theory and computer simulation. It promises a highly sensitive and label-free detection biosensor for point-of-care applications such as neurosciences.
Fiber optic localized surface plasmon resonance (LSPR) sensors have become an effective tool in refractive index (RI) detection for biomedical applications because of their high sensitivity. However, using conventional optical fiber has caused limitations in implanting the sensor in the body. This research presents the design and construction of a new type of polymer-based LSPR sensors to address this issue. Also, finite element method (FEM) is used to design the sensor and test it theoretically. The proposed polymer optical fiber (POF) based on citrate is biocompatible, flexible, and degradable, with a rate of 22% and 27 over 12 days. The step RI structure utilizes two polymers for light transmission: poly (octamethylene maleate citrate) (POMC) as the core and poly (octamethylene citrate) (POC) as the cladding. The POF core and cladding diameters and lengths are 700 µm, 1400 µm, and 7 cm, respectively. The coupling efficiency of light to the POF was enhanced using a microsphere fiber optic tip. The obtained results show that the light coupling efficiency increased to 77.8%. Plasma surface treatment was used to immobilize gold nanoparticles (AuNPs) on the tip of the POF, as a LSPR-POF sensor. Adsorption kinetics was measured based on the pseudo-first-order model to determine the efficiency of immobilizing AuNPs, in which the adsorption rate constant (k) was obtained be 8.6 × 10–3 min−1. The RI sensitivity of the sensor in the range from 1.3332 to 1.3604 RIU was obtained as 7778%/RIU, and the sensitivity was enhanced ~ 5 times to the previous RI POF sensors. These results are in good agreement with theory and computer simulation. It promises a highly sensitive and label-free detection biosensor for point-of-care applications such as neurosciences.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.