“…After polishing, the electrode was immersed in ethanol absolute and abundantly washed with deionized water. Finally, the polished electrode was submitted to potential cycles at scan rate 25 mV s −1 in a potential range from −1.0 to +1.0 V vs. SCE in 0.1 mol L −1 H 2 SO 4 solution until to obtain a stable voltammetric profile [31,32]. The electrode surface was coated with multiple additions of 10 L of 0.1% w/v PtNPs/C in DMF.…”
Section: Preparation Of Electrochemical Sensing Platformmentioning
confidence: 99%
“…After polishing, the electrode was immersed in ethanol absolute and abundantly washed with deionized water. Finally, the polished electrode was submitted to potential cycles at scan rate 25 mV s −1 in a potential range from −1.0 to +1.0 V vs. SCE in 0.1 mol L −1 H 2 SO 4 solution until to obtain a stable voltammetric profile [31,32]. The electrode surface was coated with multiple additions of 10 L of 0.1% w/v PtNPs/C in DMF.…”
Section: Preparation Of Electrochemical Sensing Platformmentioning
confidence: 99%
“…however, no method has been reported for the simultaneous estimation of ciprofloxacin, clindamycin phosphate and metronidazole in pharmaceutical mixture. [59], capillary electrophoresis [60], chemi-luminescence [61], electrochemiluminescence [62], electrochemistry [63] and electrochemical sensors [64,65]. To date, to the best of our knowledge, there is no reported thin-layer chromatography (TLC)densitometry method for the simultaneous determination mixture of CIP, CLI and MET.…”
Section: Introductionmentioning
confidence: 99%
“…The use of a standard addition of EP in the CSF solution containing the ascorbic acid allowed minimizing such interference. Open Access polyurethane composite previously used as conventional disk working electrode in the determination of many analytes, as recently reviewed [25] while here the material was used to construct the printed device as well as the electrical contacts of the SPE.…”
Section: Introductionmentioning