Biogas Production from Palm Oil Mill Effluent Using Dielectric Barrier Discharge Integrated with the Aerated Condition

Abstract: In this study, the performance of dielectric barrier discharge (DBD) with the aerated condition at discharge voltages of 15, 20, and 25 kV on the production of biogas; CH4, H2, CO, and CO2 and the removal of COD and BOD from POME were investigated. The experimental results showed that the aerated condition with a rate of 2.5 L/min at a high voltage (25 kV) produced CH4, CO, and CO2 that was 9.4, 21.5, and 19.6 times higher than the non-aerated one, respectively. The maximum cumulative volume of CH4, H2, CO, an… Show more