2014
DOI: 10.4055/cios.2014.6.3.312
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical Analysis of Operative Methods in the Treatment of Extra-Articular Fracture of the Proximal Tibia

Abstract: BackgroundTo determine relative fixation strengths of a single lateral locking plate, a double construct of a locking plate, and a tibial nail used in treatment of proximal tibial extra-articular fractures.MethodsThree groups of composite tibial synthetic bones consisting of 5 specimens per group were included: lateral plating (LP) using a locking compression plate-proximal lateral tibia (LCP-PLT), double plating (DP) using a LCP-PLT and a locking compression plate-medial proximal tibia, and intramedullary nai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
22
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(25 citation statements)
references
References 20 publications
2
22
0
1
Order By: Relevance
“…In the viewpoint of biomechanics, the structures of DLP and IMN primarily supply with support in lateral and axial directions respectively. For construct stability, the IMN fixation provided the higher stiffness, which was similar to that of Lee et al [ 19 ] who found that intramedullary nail provided a stronger stress compared with the double plates fixation. And Lee also mentioned that IMN was an ideal load sharing implant with respect to the concepts of minimally invasive surgery.…”
Section: Discussionsupporting
confidence: 82%
“…In the viewpoint of biomechanics, the structures of DLP and IMN primarily supply with support in lateral and axial directions respectively. For construct stability, the IMN fixation provided the higher stiffness, which was similar to that of Lee et al [ 19 ] who found that intramedullary nail provided a stronger stress compared with the double plates fixation. And Lee also mentioned that IMN was an ideal load sharing implant with respect to the concepts of minimally invasive surgery.…”
Section: Discussionsupporting
confidence: 82%
“…Lack of comparable control group with identical or at least similar baseline data, the IMN and plate groups in this study could have different average age, gender ratio, injury severity and et al, and therefore, the result of inter-group comparison could be misleading [11]. This could be the reason for the highest implant failure rate for IMN compared with plate and even with external fixator in this systematic review, which was hard to explain, for according to most of the biomechanical studies, IMN has the strongest stability [16][17][18].…”
Section: Discussionmentioning
confidence: 73%
“…Of the 3 studies that have confirmed the biomechanical advantages of the proposed technique, 2 investigated proximal tibial fractures with a metaphyseal-diaphyseal gap 14 , 15 , whereas the third 16 , with the participation of the author of the present study, involved the fixation technique described in the current report. The models in the third study were commercially prepared plastic bones with fracture planes that could be reduced with excellent contact; these models lacked articular or fracture-plane impaction or comminution.…”
Section: Discussionmentioning
confidence: 96%