2015
DOI: 10.1080/23335432.2015.1014849
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical analysis of the post-cam mechanism in a TKA: comparison between conventional and semi-constrained insert designs

Abstract: Posterior-stabilized (PS) total knee arthroplasty (TKA) designs were introduced to compensate for the resected or deficient posterior cruciate ligament and to avoid paradoxical anterior sliding of the femur. Knee joint stability may differ among patients and, therefore, orthopaedic companies developed several solutions to compensate for these differences. In particular, conventional PS designs are used for conventional TKA and semi-constrained PS designs are mainly applied in revision surgery or in conventiona… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 44 publications
0
8
0
Order By: Relevance
“…Even if a validated model was adopted in the present work, several assumptions were made during the implementation of the FE models: first, the different structures are based on only one geometry so no variation in the anatomy of the specimen was taken in consideration; however, this approach has already been used in literature studies for similar knee biomechanical analyses [28,36,39,40]. Only one implant design was chosen to represent each level of constraint, but it is to be noted that the aim of the study was to compare 2 different constrain levels and not 2 specific designs.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Even if a validated model was adopted in the present work, several assumptions were made during the implementation of the FE models: first, the different structures are based on only one geometry so no variation in the anatomy of the specimen was taken in consideration; however, this approach has already been used in literature studies for similar knee biomechanical analyses [28,36,39,40]. Only one implant design was chosen to represent each level of constraint, but it is to be noted that the aim of the study was to compare 2 different constrain levels and not 2 specific designs.…”
Section: Discussionmentioning
confidence: 99%
“…As revision TKA solutions, the Legion Revision Condylar Constrain Knee (Smith & Nephew, Memphis, TN) and the RT-PLUS Rotating Hinged prostheses (Smith & Nephew, Memphis, TN) were taken respectively as CCK and RTH implants. The CCK implant used constrains, as reported by previous study [28], varus-valgus, and internal-external rotations together with mediolateral translation.…”
Section: Geometrymentioning
confidence: 99%
See 2 more Smart Citations
“…Modern finite element models are usually based on medical scans and possess a high accuracy of anatomical realism fundamental for the development of appropriate, reliable and effective tools aimed at supporting clinically-tailored questions 1 . Besides the simulation of the native joints, models are widely used for the prediction of the effects of degenerative pathologies, traumatic events as well as surgical repair and replacement strategie [2][3][4][5][6][7][8] . In particular, they are used for subject-specific analyses and for guiding the surgical pre-planning phase by comparing the effect of different designs of knee prostheses on the same patient [9][10][11][12][13] .…”
Section: Introductionmentioning
confidence: 99%