2021
DOI: 10.1016/j.injury.2021.02.077
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical Comparison of Fibertape Device Repair Techniques of Ligamentous Lisfranc Injury in a Cadaveric Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(23 citation statements)
references
References 37 publications
0
23
0
Order By: Relevance
“…Eight matched fresh-frozen pairs of human cadaveric transtibial specimens (midtibia/fibula to toes; 16 specimens total) without preexisting foot deformity were obtained (Anatomy Gifts Registry) and prepared according to previous work. 7 , 24 The cohorts consisted of 5 male and 3 female donors with an average age of 50 years (range, 25-68), an average height of 69 inches (range, 64-71), and an average weight of 158 lb (range, 115-260). All specimens were thawed overnight.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Eight matched fresh-frozen pairs of human cadaveric transtibial specimens (midtibia/fibula to toes; 16 specimens total) without preexisting foot deformity were obtained (Anatomy Gifts Registry) and prepared according to previous work. 7 , 24 The cohorts consisted of 5 male and 3 female donors with an average age of 50 years (range, 25-68), an average height of 69 inches (range, 64-71), and an average weight of 158 lb (range, 115-260). All specimens were thawed overnight.…”
Section: Methodsmentioning
confidence: 99%
“…Careful dissection involved the removal of the dorsal subcutaneous tissue while preserving the capsular attachments of the midfoot and maintaining the tie rod mechanism of the arch, which was performed according to previously published work. 21 , 24 , 38 Miniature screws (2-mm head, 4-mm length), used as coordinate markers for diastasis measurements, were inserted into the 2MT, MC, and IC, which were predrilled with a Kirschner wire for pilot holes ( Figure 1 ). Two screws were inserted within each bone and placed as close to the joints as possible without disrupting the path of operative repair to provide an accurate measurement of diastasis at each joint ( Figure 1B ).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations