2019
DOI: 10.1155/2019/9687127
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical Effects of Different Auxiliary-Aligner Designs for the Extrusion of an Upper Central Incisor: A Finite Element Analysis

Abstract: Aim. To evaluate the biomechanical effects of four different auxiliary-aligner combinations for the extrusion of a maxillary central incisor and to define the most effective design through finite element analysis (FEA). Materials and Methods. A full maxillary arch (14 teeth) was modelled by combining two different imaging techniques: cone beam computed tomography and surface-structured light scan. The appliance and auxiliary element geometries were created by exploiting computer-aided design (CAD) procedures. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
45
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 55 publications
(46 citation statements)
references
References 25 publications
1
45
0
Order By: Relevance
“…We tried to use the loading condition of 0.15 mm which was used in previous studies [ 19 ], but the analysis did not converge due to excessive deformation of the PDL in the extrusion attachment model. The reason for this is the material properties of PDL reported in the previous literature use stress–strain curve values, whereas, our study was applied in the hyperelastic properties were considered using the Ogden model [ 19 , 23 ]. Therefore, the stresses and strains generated in the PDL have been shown to be different between previous and our studies.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…We tried to use the loading condition of 0.15 mm which was used in previous studies [ 19 ], but the analysis did not converge due to excessive deformation of the PDL in the extrusion attachment model. The reason for this is the material properties of PDL reported in the previous literature use stress–strain curve values, whereas, our study was applied in the hyperelastic properties were considered using the Ogden model [ 19 , 23 ]. Therefore, the stresses and strains generated in the PDL have been shown to be different between previous and our studies.…”
Section: Discussionmentioning
confidence: 99%
“…RTA was designed for each orthodontic treatment situation, and RTA was implemented with thickness of 0.3 mm based on previous literature ( Figure 2 b) [ 19 ]. The material properties of each component except for PDL were applied with reference to previous literature ( Table 1 ) [ 18 , 19 , 22 , 23 ].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations