2017
DOI: 10.1016/j.clinbiomech.2017.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanical testing of a PEEK-based dynamic instrumentation device in a lumbar spine model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
24
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 19 publications
(25 citation statements)
references
References 31 publications
1
24
0
Order By: Relevance
“…This model provides defect region with controllable dynamic stimulation and also enlighten us the mechanism of mechanical signal transmission and the relationship between physiological and mechanical‐induced regeneration. (Herren et al, ).…”
Section: Discussionmentioning
confidence: 99%
“…This model provides defect region with controllable dynamic stimulation and also enlighten us the mechanism of mechanical signal transmission and the relationship between physiological and mechanical‐induced regeneration. (Herren et al, ).…”
Section: Discussionmentioning
confidence: 99%
“…To simulate the loading of a gait cycle, rotational angles in three directions were applied to the instrumented model. However, the ROM of the instrumented spine are significantly reduced compared to the native spine when loaded by the same moment [1]. Therefore, two simulations were conducted to simulate a worst case and a best case scenario for the PDSD.…”
Section: Methodsmentioning
confidence: 99%
“…For validating the instrumented spine model, the simulated ROM was compared to the experimental ROM of the instrumented cadaveric spine specimen (Tab. 2) [1]. To simulate the loading of a gait cycle, rotational angles in three directions were applied to the instrumented model.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, posterior dynamic stabilization systems (PDSSs) with reduced stiffness were developed. The PDSS aims to maintain the healthy biomechanics of the spine by preventing the hypermobility of a mildly degenerated disc or after a decompression surgery, as well as preventing the onset of an adjacent segment disease (Fujiwara et al, 2000;Herren et al, 2017;Krismer et al, 2000;Lee et al, 2014;Tanaka et al, 2001). Clinical studies can be found in the literature, in which a successful stabilization of the treated segment is reported (Lee et al, 2014;Lee et al, 2016).…”
Section: Introductionmentioning
confidence: 99%