2023
DOI: 10.1007/s10544-023-00666-y
|View full text |Cite
|
Sign up to set email alerts
|

Biosensors; noninvasive method in detection of C-reactive protein (CRP)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 47 publications
0
3
0
Order By: Relevance
“…43,44 There are several innovative methods developed for the detection of CRP with varying degrees of sensitivity. 44,45 The plasmonic ELISA utilizes etched Ag-coated Au nanobipyramids for multicolorimetric detection and achieves an LOD of 0.09 ng/ mL. 46 The fluorescent fullerene nanoparticle-based LFIA can detect CRP concentrations between 0.1 and 10 ng/mL in serum in just 15 min.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…43,44 There are several innovative methods developed for the detection of CRP with varying degrees of sensitivity. 44,45 The plasmonic ELISA utilizes etched Ag-coated Au nanobipyramids for multicolorimetric detection and achieves an LOD of 0.09 ng/ mL. 46 The fluorescent fullerene nanoparticle-based LFIA can detect CRP concentrations between 0.1 and 10 ng/mL in serum in just 15 min.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Currently, the detection limit of CRP in conventional enzyme-linked immunosorbent assay (ELISA) can reach the level of 0.1 ng/mL. , There are several innovative methods developed for the detection of CRP with varying degrees of sensitivity. , The plasmonic ELISA utilizes etched Ag-coated Au nanobipyramids for multicolorimetric detection and achieves an LOD of 0.09 ng/mL . The fluorescent fullerene nanoparticle-based LFIA can detect CRP concentrations between 0.1 and 10 ng/mL in serum in just 15 min .…”
Section: Resultsmentioning
confidence: 99%
“…Currently, common detection methods include fluorescence [53, 54], electrochemical [55, 56], colorimetric [57, 58], and capillary electrophoresis [59, 60]. Although the above methods can provide accurate detection in diagnosis, they all have more limitations, such as complex and expensive instruments, high requirements for operating techniques, or time‐consuming tests [61–63]. And the cost of providing health care in centralized facilities, such as hospitals, is increasing [64, 65].…”
Section: Introductionmentioning
confidence: 99%