2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
DOI: 10.1109/iembs.2001.1018869
|View full text |Cite
|
Sign up to set email alerts
|

Blood and wall signal simulator for Doppler ultrasound signal analysis algorithm development

Abstract: Abstract-Doppler ultrasound instruments, used for the detection and monitoring of vascular disease, require a means of separating the large, low frequency Doppler signal from the vessel wall from the signal arising from blood followed by a means of analysing the blood flow signal in order to characterise the flow conditions. This is normally achieved by using a high-pass filter that removes the signal reflected from the vessel wall. Unfortunately, the filter also removes the low frequency Doppler signals arisi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…The Doppler ultrasound blood flow signal with clutter components can be simulated based on physical models [18]. Here, the ultrasound transmitting frequency is 5 MHz, the sampling frequency is set at 12.8 kHz, the velocity of the sound is 1,540 m/s, the sampling volume contains whole blood vessel.…”
Section: Applications To Simulated Doppler Ultrasound Signalsmentioning
confidence: 99%
“…The Doppler ultrasound blood flow signal with clutter components can be simulated based on physical models [18]. Here, the ultrasound transmitting frequency is 5 MHz, the sampling frequency is set at 12.8 kHz, the velocity of the sound is 1,540 m/s, the sampling volume contains whole blood vessel.…”
Section: Applications To Simulated Doppler Ultrasound Signalsmentioning
confidence: 99%
“…A computer simulation's model of the quadrature Doppler signals from wall and blood proposed by Fish et al [8] is used to simulate Doppler signals. According to this model, the combined Doppler signal is given by:…”
Section: Methodsmentioning
confidence: 99%
“…It is hard to be cured completely, and thus prevention of its occurrence is of great importance. In the initial stage of the vascular stenosis disease, the blood flow distribution begins to be disturbed [1,2]. It is significant for the prevention and early diagnosis of the disease to obtain complete blood components exactly, and evaluate the dynamic state of blood flow distribution close to the vessel wall in time.…”
Section: Introductionmentioning
confidence: 99%