Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study

Abstract: Abstract. The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vessel. An imaging system for combined photoacoustic and high-frequency ultrasound microscopy is presented. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-fiel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
27
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 40 publications
(28 citation statements)
references
References 28 publications
1
27
0
Order By: Relevance
“…[26] PACT; pulsed laser with 680 nm modulation amplitude 2.51%/% StO 2 in-vivo mouse [14] PAS; pulsed laser with 760 nm modulation amplitude 1.06%/% StO 2 in-vivo human blood [27] PAM; pulsed laser with 570 nm modulation amplitude 0.12%/% StO 2 in-vivo Phantom (cornstarch + gelatin)…”
Section: Supporting Informationmentioning
confidence: 99%
“…[26] PACT; pulsed laser with 680 nm modulation amplitude 2.51%/% StO 2 in-vivo mouse [14] PAS; pulsed laser with 760 nm modulation amplitude 1.06%/% StO 2 in-vivo human blood [27] PAM; pulsed laser with 570 nm modulation amplitude 0.12%/% StO 2 in-vivo Phantom (cornstarch + gelatin)…”
Section: Supporting Informationmentioning
confidence: 99%
“…A peripheral component interconnect (PCI) motion card (NI7350, National Instruments Inc., Texas) was used to control a highprecision three-axis motion stage with three integrated stepper motors (23Y002D-LW8, Anaheim Automation, California). Fast scanning was accomplished with a voice-coil actuator as previously described 25,26 while vertical and elevational translation were accomplished using the stepper motors.…”
Section: Experiments Setupmentioning
confidence: 99%
“…25 Pulsed color Doppler ultrasound was used for flow velocity estimation. A sequence of modulated ultrasound pulses was transmitted along a certain Doppler angle, and the flow velocities were calculated from detected phase shifts in received echoes.…”
Section: Blood Flow Estimation Using Doppler Ultrasoundmentioning
confidence: 99%
See 1 more Smart Citation
“…The high detection efficiency of intrinsic optical absorbers (e.g., oxy-hemoglobin (HbO2) and deoxy-hemoglobin (HbR) [3,4]) enables OR-PAM to provide label-free, high-resolution [5,6], functional imaging of fine structures [7]. OR-PAM has already demonstrated broad biomedical applications in the fields of neurology [8], ophthalmology [9][10][11][12], and vascular biology [13].…”
mentioning
confidence: 99%