Body composition monitoring in children and adolescents: reproducibility and reference values

Abstract: There is an increasing need for suitable tools to evaluate body composition in paediatrics. The Body Composition Monitor (BCM) shows promise as a method, but reference values in children are lacking. Twenty children were included and measured twice by 4 different raters to asses inter- and intra-rater reproducibility of the BCM. Reliability was assessed using the Bland-Altman method and by calculating intraclass correlation coefficients (ICCs). The intra-rater ICCs were high (≥ 0.97) for all parameters measure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(16 citation statements)
references
References 37 publications
0
12
0
3
Order By: Relevance
“…Body cell waters were measured by a whole‐body bioimpedance spectroscopy device, Body Composition Monitor (BCM, Fresenius Medical Care). Reliability of the BCM device has been proved to be high both in general population and dialysis paients 18,19 . To reduce operator variability, according to the manufacturer's instructions, all BISs were performed by the same operators.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Body cell waters were measured by a whole‐body bioimpedance spectroscopy device, Body Composition Monitor (BCM, Fresenius Medical Care). Reliability of the BCM device has been proved to be high both in general population and dialysis paients 18,19 . To reduce operator variability, according to the manufacturer's instructions, all BISs were performed by the same operators.…”
Section: Methodsmentioning
confidence: 99%
“…Reliability of the BCM device has been proved to be high both in general population and dialysis paients. 18,19 To reduce operator variability, according to the manufacturer's instructions, all BISs were performed by the same operators. A well-trained renal physician and a dialysis nurse carried out the measurements approximately 30 min before the HD session.…”
Section: Measurements Of Body Cell Watersmentioning
confidence: 99%
“…On average, three-year-olds have total body water of 7 to 11 L depending on their weight and sex. At 10 years old, there is between 15 and 25 L depending on sex and age, and at 18 years old between 35 and 50 L for boys and between 25 and 38 L for girls [ 39 , 40 , 41 ]. A new method using isotope tracking (2 H) allows investigation of water turnover (water used by the body each day), confirming that age and body size were significantly associated with water turnover, as were physical activity, socioeconomic status, and environmental characteristics (altitude, air temperature) [ 42 ].…”
Section: Overall Benefits Of Hydrationmentioning
confidence: 99%
“…The tests were carried out according to a standard protocol in accordance with the manufacturer's recommendations without shoes or socks, with clean and dried feet, and wearing light clothing. The children were asked to (1) avoid exertion and excessive fluid intake before the test; (2) were properly prepared by their parents (point 2.2); (3) at least 30 min before the measurement, children were asked to empty their intestines and bladder; (4) the children were standing for at least 5 min before the measurement to redistribute the tissue fluids; (5) measurement was performed while standing [49][50][51][52][53].…”
Section: Fat Content Measurementmentioning
confidence: 99%