2021
DOI: 10.1088/1741-4326/ac2778
|View full text |Cite
|
Sign up to set email alerts
|

Bolometer tomography on Wendelstein 7-X for study of radiation asymmetry

Abstract: The algorithm for bolometer tomography at Wendelstein 7-X (W7-X) has been recently improved using a novel regularization functional, based on relative gradient smoothing of the sought radiation profile. It has been validated using radiation patterns provided by 3D modeling under real plasma conditions as phantoms and then applied to bolometer measurements performed during the first divertor operation phase of W7-X. The following results are presented: (1) edge-localized 2D radiation patterns with clearly resol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 69 publications
1
15
0
1
Order By: Relevance
“…Here we have reported that poloidal asymmetries in the radiation distribution have been observed for both limiter and divertor plasmas (after boronization). Similar to the description in reference [37], the magnitude of the asymmetry increases toward the high density, high radiation scenarios. This asymmetry reverses under certain plasma conditions, e.g.…”
Section: Discussion and Summarysupporting
confidence: 65%
See 4 more Smart Citations
“…Here we have reported that poloidal asymmetries in the radiation distribution have been observed for both limiter and divertor plasmas (after boronization). Similar to the description in reference [37], the magnitude of the asymmetry increases toward the high density, high radiation scenarios. This asymmetry reverses under certain plasma conditions, e.g.…”
Section: Discussion and Summarysupporting
confidence: 65%
“…However, the current version of the EMC3-Eirene code (without drifts) for 3D modeling is not yet able to quantitatively reproduce all selected local measurements simultaneously under the current experimental conditions (in particular, the existence of error fields) [52]. Some results using EMC3-Eirene code are reported in [37,51] and com-parisons with the bolometer results (in OP1.2a before boronisation) show qualitative agreements but also differences, especially in the asymmetric feature of the impurity radiation distribution.…”
Section: Discussion and Summarymentioning
confidence: 99%
See 3 more Smart Citations