Abstract: The MPBL is an effective technology in terms of heat flow transport capacity: 10 MW.m, [2],with high level adaptability. A bond graph model of such a system is proposed in this paper. The model is dynamic, qualitative, configurable and pays particular attention to the dynamic of the transient regime. It aims at being a tool dedicated to designing the different components of a MPBL. It is also used for a physical analysis of the system in different operating conditions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…Interpolations giving the evolution of thermo physical properties are specifically developed for the current project with accuracy care, and are presented in our article (Kebdani et al 2015).…”
Section: Description Of the Dynamic Bond Graph Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Interpolations giving the evolution of thermo physical properties are specifically developed for the current project with accuracy care, and are presented in our article (Kebdani et al 2015).…”
Section: Description Of the Dynamic Bond Graph Modelmentioning
confidence: 99%
“…The choice of the 13 companies involved in the current project has been oriented towards 2-Phases Loop Mechanically Pumped (2-PLMP). Such systems are undoubtedly the most efficient in terms of heat transfer (Kebdani et al 2015), (Lachassagne 2010) and (Serin 2007) .…”
Section: Introduction and State Of The Artmentioning
confidence: 99%
See 1 more Smart Citation
“…These advantages extend the use of BPC. For instance, they equip power electronics cooling systems [1]. A dynamic study of this condenser is necessary to better understand the transitional behavior of this exchanger.…”
Section: Introductionmentioning
confidence: 99%
“…The choice of the 13 companies involved in the current project has been oriented towards 2-Phases Loop Mechanically Pumped (2-PLMP). Such systems are undoubtedly the most efficient in terms of heat transfer (Kebdani et al 2015), (Lachassagne 2010) and (Serin 2007) . Indeed, in addition to their architectural flexibility and compactness, they guarantee appropriate cooling using a pump.…”
Section: Introduction and State Of The Artmentioning
confidence: 99%