1981
DOI: 10.1007/bf00542374
|View full text |Cite
|
Sign up to set email alerts
|

Bonding mechanism between alumina and niobium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
32
0

Year Published

1984
1984
2014
2014

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 91 publications
(33 citation statements)
references
References 3 publications
1
32
0
Order By: Relevance
“…The copper-oxygen phase 8 Morozumi et al [27] report ≈50% bonded area after 1 h, 8.8 MPa, hv bonding at 1600°C. Turwitt et al [37] report that after a 2 h, 10 MPa hv bonding cycle at 1700°C, ≈10-20% of the interface remains unbonded, suggesting that porosity removal is slow even at substantially higher temperature.…”
Section: Brazing Using Copper-cuprous Oxide Eutectic and Joint Propermentioning
confidence: 99%
See 2 more Smart Citations
“…The copper-oxygen phase 8 Morozumi et al [27] report ≈50% bonded area after 1 h, 8.8 MPa, hv bonding at 1600°C. Turwitt et al [37] report that after a 2 h, 10 MPa hv bonding cycle at 1700°C, ≈10-20% of the interface remains unbonded, suggesting that porosity removal is slow even at substantially higher temperature.…”
Section: Brazing Using Copper-cuprous Oxide Eutectic and Joint Propermentioning
confidence: 99%
“…Generally, for conventional high vacuum (hv; ≈10 -3 Pa) diffusion bonding, studies have focussed on the temperature range 1500-1950°C, with bonding times of several hours, and a bonding load typically of the order of 10 MPa [27][28][29][30][31]. Bonding temperature reductions of up to 500°C relative to hv bonding can be achieved by the use of ultrahigh vacuum (uhv; ≈10 -8 Pa) conditions coupled with sputter cleaning of the bonding surfaces [32].…”
Section: Diffusion Bonding Conditions and Joint Propertiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Joints between polycrystalline niobium and polycrystalline alumina typically exhibited either lower fracture energies [34] or fracture energies nearer to the lower bicrystal values [55]. A limited number of strength measurements indicated that joints processed at 1600°C under hv conditions failed at tensile stresses of the order of 100-150 MPa [28,32].…”
Section: Alumina/niobium Diffusion Bondingmentioning
confidence: 99%
“…Generally, for conventional high-vacuum (hv; ≈10 -3 Pa) diffusion bonding, bonding temperatures were 1500-1950°C, bonding times were typically several hours, and the applied load was generally of the order of 10 MPa [28,32,36,37,54]. The use of ultrahigh-vacuum (uhv; ≈10 -8 Pa)…”
Section: Alumina/niobium Diffusion Bondingmentioning
confidence: 99%