2013
DOI: 10.1080/01694243.2013.860676
|View full text |Cite
|
Sign up to set email alerts
|

Bonding strength of oak with different adhesives after humid-water-heat tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 3 publications
1
5
0
Order By: Relevance
“…The results obtained in this study are in agreement with those of other researchers, who have reported a reduction in the water resistance of tested samples immediately after exposure to the effect of cold water, or in combination with a conditioning process [42,43,[48][49][50]. Analyses of the strength of joints compared with the maximum values showed, unambiguously for all systems, that the PUR adhesive used, when applied both to impregnated and unprotected wood, provides the technical possibility of obtaining water-resistant glued joints.…”
Section: Discussionsupporting
confidence: 93%
“…The results obtained in this study are in agreement with those of other researchers, who have reported a reduction in the water resistance of tested samples immediately after exposure to the effect of cold water, or in combination with a conditioning process [42,43,[48][49][50]. Analyses of the strength of joints compared with the maximum values showed, unambiguously for all systems, that the PUR adhesive used, when applied both to impregnated and unprotected wood, provides the technical possibility of obtaining water-resistant glued joints.…”
Section: Discussionsupporting
confidence: 93%
“…The most important factors affecting the shear strength of wood and wood-based material are the wood species, adhesive type, wood density, log temperature during the veneer peeling or clipping, veneer drying temperature, and the relative moisture content of wood (Demirkir et al 2013). Yorur et al (2014) studied the effect of humidity-water-heat tests on the bonding strength of impregnated oak (Quercus petraea spp.) bonded with UF, Desmodur-VTKA (Desmodur-Vinil trieketonol acetate), and polyvinyl acetate (PVAc) adhesives.…”
Section: Introductionmentioning
confidence: 99%
“…Pizzi and Mittal (2003) stated that polyurethane adhesives have a higher bonding strength and a higher tolerance against humidity. According to another study, PU is the least affected one compared to PVAc in the steam test (Yorur et al 2014).…”
Section: Pilot-hole Effectsmentioning
confidence: 99%