Boronic Acid Decorated Graphene Nano Flakes for Glucose Sensing in Diabetes: A DFT Prediction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 19 publications
1
4
0
Order By: Relevance
“…On the side of electronic parameters (see Table 1), the energy gap obtained was 4.34 eV. This value is similar to that reported by Darwish et al., [45] and larger with respect to other graphene‐like systems [49] . Clearly, Gap LH decreases 0.45 eV with respect to its bare counterpart, nevertheless; the semiconductor‐like behavior is maintained.…”
Section: Resultssupporting
confidence: 86%
See 1 more Smart Citation
“…On the side of electronic parameters (see Table 1), the energy gap obtained was 4.34 eV. This value is similar to that reported by Darwish et al., [45] and larger with respect to other graphene‐like systems [49] . Clearly, Gap LH decreases 0.45 eV with respect to its bare counterpart, nevertheless; the semiconductor‐like behavior is maintained.…”
Section: Resultssupporting
confidence: 86%
“…This value is similar to that reported by Darwish et al, [45] and larger with respect to other graphene-like systems. [49] Clearly, Gap LH decreases 0.45 eV with respect to its bare counterpart, nevertheless; the semiconductor-like behavior is maintained. This decrement is associated with sensing glucose.…”
Section: Bnns-glucose Complex Analysismentioning
confidence: 94%
“…The limitations of the traditional enzymatic glucose sensing using glucose oxidase are cost, length, instability, and proneness to denaturation of enzymes. BA derivatives have been reported as important binding agents for glucose and HbA1c sensing . The proposed electrochemical sensor in this work relies on the formation of a boronate ester complex between BA attached with ZIF-8 NPs and the cis -diol moieties of the glucose molecule.…”
Section: Resultsmentioning
confidence: 99%
“…The absorbance of each Hb solution in the pH 6.0 buffer was measured using the UV−vis spectrophotometer at the established wavelength of 406 nm with the contribution of isosbestic point of Hb. 55 A second calibration line was constructed by plotting the absorbance values against the corresponding concentrations (mg/mL) of the Hb solutions in the pH 6.0 buffer (y = 0.1571x + 0.0019 (R 2 = 0.9987). These calibration lines serve as reference tools, establishing a quantitative relationship between absorbance values and the concentration of Hb solutions.…”
Section: Optimization Of Adsorption Conditions 221 Hb Calibration Linesmentioning