BRS implantation in long lesions requiring device overlapping: myth or reality?

Abstract: Dealing with bioresorbable vascular scaffolds (BVS) implantation in long lesions requiring device overlapping in this particular moment might seem a little provocative for several reasons. First, most studies testing BVS have focused on their safety and efficacy profile in simple patients with simple lesions. Second, ABSORB II did not meet its primary endpoint, while ABSORB III showed a higher rate of target vessel-myocardial infarction (TV-MI) at 2 years. Third, data on porcine model showed that overlapping z… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…Late ones fail at malapposition (35%), discontinuity (31%), peri-strut low intensity area (19%) and incomplete lesion coverage (12%) [ 27 ]. Also the device overlap seems to be a factor increasing the scaffold thrombosis rate [ 28 ]. The study group of Polimeni et al enrolled 183 patients with ST-segment myocardial infarction in their study and could demonstrate that the scaffold thrombosis rate was reduced when an optimized implantation technique was used [ 29 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Late ones fail at malapposition (35%), discontinuity (31%), peri-strut low intensity area (19%) and incomplete lesion coverage (12%) [ 27 ]. Also the device overlap seems to be a factor increasing the scaffold thrombosis rate [ 28 ]. The study group of Polimeni et al enrolled 183 patients with ST-segment myocardial infarction in their study and could demonstrate that the scaffold thrombosis rate was reduced when an optimized implantation technique was used [ 29 ].…”
Section: Discussionmentioning
confidence: 99%
“…The study group of Polimeni et al enrolled 183 patients with ST-segment myocardial infarction in their study and could demonstrate that the scaffold thrombosis rate was reduced when an optimized implantation technique was used [ 29 ]. Many recent studies tried to find predictors for scaffold failure and figured out that the implantation technique is a very important factor in reducing cardiac events [ 28 , 30 36 ]. The use in acute coronary syndroms studied by Anadol et al seems to be safe as well [ 37 ].…”
Section: Discussionmentioning
confidence: 99%