2023
DOI: 10.3390/chemosensors11010063
|View full text |Cite
|
Sign up to set email alerts
|

Bulk Modification of Sonogel–Carbon with Polyaniline: A Suitable Redox Mediator for Chlorophenols Detection

Abstract: In this work, the development and characterization of a new ceramic material modified with polyaniline powder obtained by a high-power ultrasound sol-gel route is presented. A preliminary screening of the conducting polymer electroactivity was performed by means of cyclic voltammetry in free analyte solution. Remarkable figures of merit for 4-chloro-3-methylphenol (PCMC) determination, selected as the model organic analyte, was obtained with the developed material: the sensitivity and the limit of detection we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 34 publications
(35 reference statements)
0
3
0
Order By: Relevance
“…Overall, th CCE demonstrates superior electroanalytical performance in terms of both LDR and The validation parameters acquired for the Bi-CCE were contrasted with data for various carbon-based electrodes utilized in PCMC determination (Table 2). Overall, the Bi-CCE demonstrates superior electroanalytical performance in terms of both LDR and LOD values compared to most other carbon-based electrodes [24,34,[36][37][38]. Remarkably, slightly better, however, still comparable results were achieved using the anodically pretreated boron-doped diamond electrode with a B/C ratio of 2000 ppm [35].…”
Section: Electroanalytical Performance Of the Bi-ccementioning
confidence: 83%
See 1 more Smart Citation
“…Overall, th CCE demonstrates superior electroanalytical performance in terms of both LDR and The validation parameters acquired for the Bi-CCE were contrasted with data for various carbon-based electrodes utilized in PCMC determination (Table 2). Overall, the Bi-CCE demonstrates superior electroanalytical performance in terms of both LDR and LOD values compared to most other carbon-based electrodes [24,34,[36][37][38]. Remarkably, slightly better, however, still comparable results were achieved using the anodically pretreated boron-doped diamond electrode with a B/C ratio of 2000 ppm [35].…”
Section: Electroanalytical Performance Of the Bi-ccementioning
confidence: 83%
“…Due to the wide use of PCMC, it is necessary to monitor its content in the aquatic environment to prevent its destructive effects on both human and aquatic lives. In the literature, only a few reports on electroanalytical procedures for PCMC determination using carbon-based electrodes can be found [24,[34][35][36][37][38]. One of these reports is from our previous study, in which a voltammetric procedure for PCMC determination involving CCE modified with carbon nanotubes was detailed [24].…”
Section: Introductionmentioning
confidence: 99%
“…This issue was due to the fact that the nanocomposite’s electrical conductivity and electrocatalytic effect were not high enough. To address this issue, it is possible to dope with conductive polymers, such as polyaniline (PANI), and coat it with nanomaterials, such as gold nanoparticles (Au NPs) [ 32 ], which may lead to a lower LOD.…”
Section: Recent Advancesmentioning
confidence: 99%