2016
DOI: 10.1016/j.fusengdes.2016.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Buoyancy effects in vertical rectangular duct with coplanar magnetic field and single sided heat load

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
7
0
2

Year Published

2016
2016
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(12 citation statements)
references
References 14 publications
3
7
0
2
Order By: Relevance
“…Qualitatively similar oscillations are observed in the experiments [6]. The experimental flow cannot be reproduced in the framework of our model because at the parameters of the experiment (Gr ≈ 10 8 , Re ≈ 10 4 , Ha ≤ 800) the conditions of the two-dimensional approximation (1) are not satisfied to a sufficient degree of certainty.…”
Section: Discussionsupporting
confidence: 51%
See 1 more Smart Citation
“…Qualitatively similar oscillations are observed in the experiments [6]. The experimental flow cannot be reproduced in the framework of our model because at the parameters of the experiment (Gr ≈ 10 8 , Re ≈ 10 4 , Ha ≤ 800) the conditions of the two-dimensional approximation (1) are not satisfied to a sufficient degree of certainty.…”
Section: Discussionsupporting
confidence: 51%
“…The convection in a downward flow in a vertical round pipe and duct has been investigated experimentally [6,10,12,13] and numerically [11,31]. It has been found that the thermal convection is a critical factor determining the flow structure.…”
Section: Introductionmentioning
confidence: 99%
“…The first indications that turbulence suppression does not necessarily lead to a steady laminar convection were obtained in the experiments, such as [14,24,18]. Mixed convection in flows of mercury in pipes and ducts of various orientations with respect to gravity and imposed magnetic field were studied at Gr ≤ 10 8 , Ha ≤ 800 Re ≤ 5 × 10 4 .…”
Section: Extreme Magnetoconvectionmentioning
confidence: 99%
“…Данная зона является концентратором напряжений, значения в которой сильно зависят о технологии изготовления и наличия/отсутствия галтели. Оценка, выполненная по размаху деформаций в центральной части канала (0,19%), показывает, что допустимое число циклов составляет ~10 5 . Режим работы реактора ИТЭР предполагает работу в течение 3•10 4 циклов, т.е.…”
Section: критериальный анализ параметров температурных пульсацийunclassified
“…Теплообмен в этих условиях происходит под воздействием поперечного магнитного поля [3] и сил плавучести [4]. Экспериментальные результаты, полученные на моделях, приведены в [5][6][7]. Эти данные показывают, что для нисходящего потока в определённом диапазоне характерных параметров развиваются высокоамплитудные колебания температуры, которые связаны с вторичными крупномасштабными вихрями в потоке, вызванными совместным влиянием сил плавучести и электромагнитных сил.…”
Section: Introductionunclassified