“…High-speed switching devices produce lots of EMI noise during the fast on-off process, which usually interferes with nearby equipment through conduction or radiation [8][9][10]. Typical problems caused are measurement errors in sensors, false control signals, and interference in the gate voltages of switching devices [8].…”
Section: Inverter Layout Considerationmentioning
confidence: 99%
See 2 more Smart Citations
“…High-speed switching devices produce lots of EMI noise during the fast on-off process, which usually interferes with nearby equipment through conduction or radiation [8][9][10]. Typical problems caused are measurement errors in sensors, false control signals, and interference in the gate voltages of switching devices [8].…”
Section: Inverter Layout Considerationmentioning
confidence: 99%
“…Typical problems caused are measurement errors in sensors, false control signals, and interference in the gate voltages of switching devices [8]. Excessive noise can deteriorate control, reduce efficiency, and cause malfunctions of system.…”
Section: Inverter Layout Considerationmentioning
confidence: 99%
See 1 more Smart Citation
“…At this time, because the plate surface area facing each other is relatively large, the bus-bar is not stabilized due to the influence of the electromagnetic field. The bus-bar cannot bend in the three-axis direction when the bus-bar is placed in the switchboard, hence, the volume of the switchboard increases.Cylindrical bus-bar was developed to resolve the problems of plate-shaped bus-bars, and they can reduce the interference of electromagnetic fields from adjacent bus-bars while occupying a relatively small volume [9,10].However, in the same manner as the plate-shaped bus-bar, the electric resistance characteristic of the cylindrical bus-bar is changed due to the deformation of the joint parts by the pressing process during the fastening of the bus-bar. In addition, the current path of the joint parts is changed due to the screw, resulting in a localized temperature rise.…”
mentioning
confidence: 99%
“…Cylindrical bus-bar was developed to resolve the problems of plate-shaped bus-bars, and they can reduce the interference of electromagnetic fields from adjacent bus-bars while occupying a relatively small volume [9,10].…”
mentioning