2012
DOI: 10.4319/lom.2012.10.10
|View full text |Cite
|
Sign up to set email alerts
|

CADICA: Continuous Automated Dissolved Inorganic Carbon Analyzer with application to aquatic carbon cycle science

Abstract: Dissolved inorganic carbon (DIC) represents a significant component of both the terrestrial and oceanic carbon cycles. An instrument for the continuous and automated analysis of dissolved inorganic carbon in the field is described. The analyzer is designed to allow collection of high-resolution (sub hourly) DIC data over prolonged field deployments without the need for labor-intensive maintenance and monitoring. The instrument sequentially acidifies an aliquot of water in gas permeable tubing through which CO … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
22
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 16 publications
(22 citation statements)
references
References 33 publications
0
22
0
Order By: Relevance
“…Johnson et al . () developed a system that continuously records pCO 2 , and instruments to measure DIC in both ocean (Sayles and Eck., ) and fluvial environments (Bass et al ., , ) have been described. These advances in measurement capability, coupled to existing automated data loggers for various hydrological and hydrochemical parameters, are enabling high‐resolution carbon budgets to be calculated in small, hydrologically responsive systems.…”
Section: Introductionmentioning
confidence: 97%
“…Johnson et al . () developed a system that continuously records pCO 2 , and instruments to measure DIC in both ocean (Sayles and Eck., ) and fluvial environments (Bass et al ., , ) have been described. These advances in measurement capability, coupled to existing automated data loggers for various hydrological and hydrochemical parameters, are enabling high‐resolution carbon budgets to be calculated in small, hydrologically responsive systems.…”
Section: Introductionmentioning
confidence: 97%
“…Stability of the CRDS Carbon Isotope Analyzer Picarro CRDS Carbon Isotope Analyzers have been applied used for a wide range of measurements including the partial pressure and δ 13 C of CO 2 in the surface ocean (Becker et al 2012;Friedrichs et al 2010), concentration, and δ 13 C of DIC in the surface ocean (Bass et al 2012a(Bass et al , 2012b, and partial pressure and δ 13 C of atmospheric CO 2 (Vogel et al 2013). These studies show that the analyzer is calibration free for pCO 2 measurement, yet has a baseline drift of ~0.1-0.3 per mil d -1 for δ 13 C measurements.…”
Section: Verification Of the Methodsmentioning
confidence: 99%
“…pCO 2 of the exiting gas, the volume of the sample, and the volume of the carrier gas (Bass et al 2012a(Bass et al , 2012bBandstra et al 2006;O'Sullivan and Millero 1998).…”
mentioning
confidence: 99%
“…Previously, semi‐permeable membranes have been used to introduce a range of sample types into mass spectrometers to circumvent sample handling, clean‐up and separation steps, and have been used in portable instruments for continuous monitoring of volatile organic compounds . Recently, a portable system was developed for the quasi‐continuous analysis of dissolved inorganic carbon in environmental waters using expanded PTFE (ePTFE) tubing developed for medical applications . ePTFE tubing has also been successfully used to measure soil respiration by diffusion …”
mentioning
confidence: 99%