2018
DOI: 10.1016/j.apenergy.2018.02.105
|View full text |Cite
|
Sign up to set email alerts
|

Calculation and analysis of efficiencies and annual performances of Power-to-Gas systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
40
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(41 citation statements)
references
References 28 publications
0
40
0
1
Order By: Relevance
“…Options to consider in such models are not only hydrogen storage, CO 2 storage and batteries, but also variable production, start‐up and shutdown of electrolysers and bio‐P2M reactors. Bioreactors cannot be stopped at will, microorganisms may be sensitive to changes in hydrogen input and the operational load may all affect the performance . Further research is needed to assess such changes and how long hydrogen supply can be interrupted.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Options to consider in such models are not only hydrogen storage, CO 2 storage and batteries, but also variable production, start‐up and shutdown of electrolysers and bio‐P2M reactors. Bioreactors cannot be stopped at will, microorganisms may be sensitive to changes in hydrogen input and the operational load may all affect the performance . Further research is needed to assess such changes and how long hydrogen supply can be interrupted.…”
Section: Discussionmentioning
confidence: 99%
“…Bioreactors cannot be stopped at will, microorganisms may be sensitive to changes in hydrogen input and the operational load may all affect the performance. 59 Further research is needed to assess such changes and how long hydrogen supply can be interrupted. A better understanding of the time dependence of renewable energy supply in terms of scale and dynamic operation is warranted, such as the impact of the frequency of switching the electrolyser on and off.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The power consumption during cold standby and for safety infrastructure is based on a 1.074 MW plant and is proportionally adjusted to each size of electrolyser assessed (Frank et al, 2018). To allow gas storage at 500 bar, H 2 is compressed requiring 2.2 kWh/kg H 2 (W comp ) (Linde, 2014).…”
Section: Power-to-hydrogen Model and Optimization Proceduresmentioning
confidence: 99%
“…Based on an HTE system model calibrated by cell experiments, reference [18] described an operating state including the distribution of electric power to electrolyzer, steam generator, furnace and other auxiliaries. Reference [17] conducted a comprehensive steady-state efficiency calculation in an analytical approach for a generic P2G system considering various of modules and sub-systems. Note that the parametric study or optimization was not further discussed to improve the system performance in [18] and [17].…”
mentioning
confidence: 99%