Calculation/comparison of dose to point “H” according to the ABS recommendations for HDR brachytherapy for carcinoma of the cervix to the dose to point “A” based on the revised manchester system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…These findings match the results of Howell et al . [7], showing that a plan normalized to new point A generated slightly higher doses. There is no literature describing the impact on clinical outcomes due to a 2-3% increase in overall dose.…”
Section: Discussionmentioning
confidence: 99%
“…These findings match the results of Howell et al . [7], showing that a plan normalized to new point A generated slightly higher doses. There is no literature describing the impact on clinical outcomes due to a 2-3% increase in overall dose.…”
Section: Discussionmentioning
confidence: 99%
“…The mean percentage difference of TRAK and V 100 (cc) values was 4.29% and 8.35%, respectively, which showed that A icru89 plan has higher values of these parameters than (24), also showed that the plan normalized to a new Point A generated slightly higher doses. These studies proved that the dose to V 100% increases with the increase in the TRAK value.…”