2006 IEEE 8th International Conference on Properties and Applications of Dielectric Materials 2006
DOI: 10.1109/icpadm.2006.284250
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of Electric-field Distribution and Research on Characteristics of Shielding Ring along the Long-rod Post Porcelain Insulators Used in 1000kv System

Abstract: In this paper, the finite element method is used to calculate the three-dimensional electric-field distribution of long-rod post porcelain insulators used in 1000kv system. The electric-field distribution is simulated in the condition of varied position, varied major radius and varied section dimension of the shielding ring. The effect of these factors to the external insulation characteristics of post porcelain insulators is analyzed. The electric-field distribution at the line side and the grounding flange c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…As stated above, due to the effect of stray capacitance, the VDR of the test CVD exceeded the requirement of class 0.2 even adjusting the position of the medium-voltage tap. Some studies indicate that the metal shield and grading ring can compensate for the effect of stray capacitance, improve the distribution of electric field, and boost the voltage endurance and insulation strength of the high-voltage apparatus accordingly [14,15,39]. In this section, we analyze the effect of the shield on the VDR of the test CVD and optimize the structure parameters of the shield to reduce VDR further.…”
Section: Effect Of the Shield On The Vdr Of The Cvdmentioning
confidence: 99%
“…As stated above, due to the effect of stray capacitance, the VDR of the test CVD exceeded the requirement of class 0.2 even adjusting the position of the medium-voltage tap. Some studies indicate that the metal shield and grading ring can compensate for the effect of stray capacitance, improve the distribution of electric field, and boost the voltage endurance and insulation strength of the high-voltage apparatus accordingly [14,15,39]. In this section, we analyze the effect of the shield on the VDR of the test CVD and optimize the structure parameters of the shield to reduce VDR further.…”
Section: Effect Of the Shield On The Vdr Of The Cvdmentioning
confidence: 99%