2013
DOI: 10.1111/opo.12046
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of power and field of view of keratoprostheses

Abstract: We present a strategy on the calculation of keratoprostheses and variation of the design (e.g. back surface curvature) to help to avoid aniseikonia in case of binocular vision (e.g. one phakic eye and one with keratoprosthesis).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…On the other hand side, there are reports that the central visual field is not affected with implantation of those inlays [23, 26], but detailed clinical data has not been published up to now. Especially, the mid-to-peripheral visual field may be affected by a KAMRA, as it has been shown for other aperture restricting optical implants such as keratoprostheses [36]. Therefore, in the present paper, we address the effect of light attenuation for variations of field angle and pupil size in an optical simulation model.…”
Section: Discussionmentioning
confidence: 94%
“…On the other hand side, there are reports that the central visual field is not affected with implantation of those inlays [23, 26], but detailed clinical data has not been published up to now. Especially, the mid-to-peripheral visual field may be affected by a KAMRA, as it has been shown for other aperture restricting optical implants such as keratoprostheses [36]. Therefore, in the present paper, we address the effect of light attenuation for variations of field angle and pupil size in an optical simulation model.…”
Section: Discussionmentioning
confidence: 94%
“…A plethora of studies have been conducted regarding the clinical outcomes of B-KPro surgery, yet very few reports focused on the optical properties of the device and its intrinsic ability to provide normal vision. [10][11][12]17 There has been confusion as to whether poor visual outcomes in some patients could be attributed to optical limitations of the device. The present study was designed to reevaluate the optics of the type I B-KPro, validate the manufacturing process and specifications, and determine the optical limits in achieving normal, reasonably glare-free visual acuity.…”
Section: Discussionmentioning
confidence: 99%
“…The surgical and clinical outcomes of patients implanted with the B-KPro have been previously published to elucidate the clinical performance of the device, 8 , 9 and help surgeons optimize patient selection and reduce postoperative surgical complications. A few studies have detailed the optical performance of the B-KPro, 10 12 however, a detailed evaluation of the intrinsic optical performance of the B-KPro simulating an aqueous environment has not been performed to International Organization for Standardization (ISO) standard bench-top methods. We have addressed this gap by adopting the ISO standards for implantable intraocular lenses (IOLs) for benchmarking the optical properties of the B-KPro type I device, which is the most frequently implanted B-KPro type.…”
Section: Introductionmentioning
confidence: 99%
“…The 16 papers included in this special issue cover a range of advances in these topics including the use of alternative basis functions for wavefront representation and beam generation, keratoprostheses and intraocular lenses, determination and analysis of aberrations, accommodation, retinal imaging, and strabismus …”
mentioning
confidence: 99%
“…Although corneal transplantation is a possible solution the limited availability of donor eyes and possible graft rejection makes the need for artificial corneas an attractive alternative. The study by Langenbucher et al . employs raytracing and PSF calculations to examine the optical consequences of commercially‐available Boston I and Boston II keratoprostheses and the potential of restoring even binocular vision.…”
mentioning
confidence: 99%