2016
DOI: 10.1589/jpts.28.3458
|View full text |Cite
|
Sign up to set email alerts
|

Calf muscle activity alteration with foot orthoses insertion during walking measured by fine-wire electromyography

Abstract: [Purpose] The purpose of the study was to assess the muscle activity change of the tibialis posterior, flexor digitorum longus, and peroneus longus during gait with orthoses. [Subjects and Methods] Sixteen healthy males participated in this study. Activity of each muscle was measured by using fine-wire and surface electromyography. Gait task was performed by the participants barefoot, with footwear and with orthoses. The electromyography data from a stance phase of each gait trial were used for analysis. The s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 20 publications
1
11
0
2
Order By: Relevance
“…18,21 Another two studies found TP activity was not significantly different between the footwear and FOs conditions (p > 0.05), although there was a decrease of around 10% (p < 0.05) from barefoot to shod and shod with either a prefabricated or custom FOs, which was not considered clinically generalisable in this review. 2,40 However, in the study that recorded kinematics and kinetics, there was also no effect of FOs on subtalar joint displacement or supination moment relative to the shoe condition. 2 There was no difference in flexor digitorum longus or PL activity between conditions.…”
Section: Criteriamentioning
confidence: 94%
“…18,21 Another two studies found TP activity was not significantly different between the footwear and FOs conditions (p > 0.05), although there was a decrease of around 10% (p < 0.05) from barefoot to shod and shod with either a prefabricated or custom FOs, which was not considered clinically generalisable in this review. 2,40 However, in the study that recorded kinematics and kinetics, there was also no effect of FOs on subtalar joint displacement or supination moment relative to the shoe condition. 2 There was no difference in flexor digitorum longus or PL activity between conditions.…”
Section: Criteriamentioning
confidence: 94%
“…Bipolar, fine-wire, intramuscular, Teflon-coated, stainless steel electrodes with uninsulated tips bent at 3 mm and 5 mm to create hooks, were attached to 23-G sterilized Cattelan needles (Unique Medical, Japan) and used for measurement of piriformis EMG activity. Insertion into the piriformis was accomplished by an experienced orthopedic surgeon 12 ) . The participants were placed in side-lying position with their dominant hand side up, and with knees flexed at 90° and hips flexed at 45°.…”
Section: Methodsmentioning
confidence: 99%
“…Kusumoto et al confirmed that the insoles combined with a metatarsal pad promoted static and dynamic balance in patients with cerebral palsy [20]. Based on the previously mentioned studies, it was found that the insoles had only one additional modification that had been applied for the correction of lower limb kinematic and kinetic abnormalities in most studies on hemiplegic gait [21,22]. In fact, patients with hemiplegia usually had variable abnormal gait performances, which were caused by different foot structures and movement defects such as a collapsed transverse arch, spastic clawing of toes, restricted ankle dorsiflexion, and plantarflexion [23].…”
Section: Introductionmentioning
confidence: 97%