2012
DOI: 10.1016/j.envpol.2012.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 35 publications
0
6
0
Order By: Relevance
“…Results from passive sampling with SPMDs, POM, and silicones generally agree within a factor of 3 with results from batch sampling although differences by a factor of ∼10 have also been observed. , In some cases, differences increased with hydrophobicity, which could be attributed to the contribution of dissolved organic carbon (DOC) bound compounds to batch sampling based results. ,, …”
Section: Passive Sampling In Watermentioning
confidence: 59%
“…Results from passive sampling with SPMDs, POM, and silicones generally agree within a factor of 3 with results from batch sampling although differences by a factor of ∼10 have also been observed. , In some cases, differences increased with hydrophobicity, which could be attributed to the contribution of dissolved organic carbon (DOC) bound compounds to batch sampling based results. ,, …”
Section: Passive Sampling In Watermentioning
confidence: 59%
“…Several studies have reported that the R s values for some polar organic contaminants generally increased with the temperature [27,64,65], although these effects were relatively small [50]. The effects of temperature on the R s might be associated with the solubility and mobility of analytes, the octanol-water partition coefficient (K ow ), and the permeability of polymers in membrane [66]. Theoretically, the increase in temperature would cause an enhancement in mobility and solubility of analytes, thus facilitating the transfer of analytes from aqueous solutions to adsorbents in the POCIS.…”
Section: Temperaturementioning
confidence: 99%
“…After determining the analyte kinetic regimes, the concentrations of the compounds that were in the integrative stage were calculated using the dissipation rate of a performance reference compound (PRC), which was spiked onto the samplers prior to their deployment (see Sections 3 and 8 in the Supporting Information for more details). d 12 -Chrysene was used as the PRC because its recovery after retrieval from the field was within the recommended range of 20% to 80%. , Only data from passive samplers that were in the integrative stage at the time of retrieval were used (see Section 8 in the Supporting Information and Table S3 for more details).…”
Section: Experimental Sectionmentioning
confidence: 99%
“…d 12 -Chrysene was used as the PRC because its recovery after retrieval from the field was within the recommended range of 20% to 80%. 36,37 Only data from passive samplers that were in the integrative stage at the time of retrieval were used (see Section 8 in the Supporting Information and Table S3 for more details).…”
Section: ■ Introductionmentioning
confidence: 99%