Calibration of a Cryogenic Turbine-Based Volumetric Flow Meter (CTVFM) Using Sub-Cooled Liquid Nitrogen and Solution for Its Practical Issues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…The liquid nitrogen is then passed through a www.cprijournal.in Vol 18(1) | June 2022 helical heat exchanger inside the sub-cooled cryostat of the sub-cooling unit maintained at 65 K. The level inside the sub-cooling unit is maintained by using another liquid nitrogen Dewar of 121-liter capacity. The detailed construction and operation of the sub-cooling unit is discussed elsewhere 12 .…”
Section: Cryogen Flow Measurement and Controlmentioning
confidence: 99%
See 2 more Smart Citations
“…The liquid nitrogen is then passed through a www.cprijournal.in Vol 18(1) | June 2022 helical heat exchanger inside the sub-cooled cryostat of the sub-cooling unit maintained at 65 K. The level inside the sub-cooling unit is maintained by using another liquid nitrogen Dewar of 121-liter capacity. The detailed construction and operation of the sub-cooling unit is discussed elsewhere 12 .…”
Section: Cryogen Flow Measurement and Controlmentioning
confidence: 99%
“…This created a need for re-calibrating the CTVFM with subcooled LN 2 (below 77 K at 0.1 MPa) to avoid the 2-phase problem and to account for the thermo-mechanical constraints appearing at cryogenic temperatures. The detailed calibration process has been discussed in [12].…”
Section: Technical Challenges and Mitigationmentioning
confidence: 99%
See 1 more Smart Citation
“…In the turbine flowmeters, the frequency generated by the rotation of a rotor is directly proportional to the flowrate. 2 These steadily calibrated devices can be applied to measure unsteady flowrates, 3 but only pulsating 4,5 or intermittent 6 ones with a lower frequency than 1 kHz can be considered.…”
Section: Introductionmentioning
confidence: 99%
“…For the flowrate measurement, many technologies and working principles have been established. The frequency caused by the impeller rotation, which is directly correlated with the flowrate, is measured in turbine flowmeters [2]. These devices, calibrated in steady state conditions, can be used to monitor unsteady flow rates [3], although only pulsing [4,5], or intermittent [6] flows with frequencies less than 1 kHz can be considered.…”
Section: Introductionmentioning
confidence: 99%