Calibration of a Photometric Cloud Condensation Nucleus Counter Designed for Deployment on a Balloon Package

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
44
1

Year Published

2001
2001
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(45 citation statements)
references
References 20 publications
0
44
1
Order By: Relevance
“…From Figs. 4 and 5 in Delene and Deshler (2000), the peak voltage appears to lag the peak number by approximately 2 s for S ϭ 0.3%. We performed an additional sensitivity run for case 3, shown in Fig.…”
Section: ϫ3mentioning
confidence: 92%
See 2 more Smart Citations
“…From Figs. 4 and 5 in Delene and Deshler (2000), the peak voltage appears to lag the peak number by approximately 2 s for S ϭ 0.3%. We performed an additional sensitivity run for case 3, shown in Fig.…”
Section: ϫ3mentioning
confidence: 92%
“…CCN spectra were recorded with a University of Wyoming thermal-gradient static-diffusion cloud chamber (CCNC-100A) Delene and Deshler 2000;Snider et al 2003). The CCN instrument optically counted the number concentration of aerosol activated to cloud drop sizes.…”
Section: B Measurement Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…The instrument itself consists of a chamber that is circular in the horizontal dimension with ports for sample intake and exhaust, a temperaturecontrolled plate on the chamber bottom, and a photodetector. The theory and operation of this instrument is described by Delene and Deshler (2000), Snider et al (2003), and Snider et al (2006). The method for creating a supersaturated environment in the CCNC-100A is similar to that for the DMT continuous flow diffusion chamber in that a sharp temperature gradient across a small space is used to establish and control the SS.…”
Section: Instruments and Calibrationmentioning
confidence: 99%
“…The detection stage lasts for 20 s during which a steady SS is maintained within the chamber (Snider et al, 2006). The entire process takes 30 to 40 s including the time needed to flush the old sample out of the chamber, admit the new sample, and achieve the steady state SS which can be as much as 15 s depending on how long it takes for the temperature gradient within the chamber to stabilize (Delene and Deshler, 2000;Snider et al, 2006).…”
Section: Instruments and Calibrationmentioning
confidence: 99%