2011
DOI: 10.1177/0954406211418420
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of a six-DOF parallel manipulator for chromosome dissection

Abstract: This article proposes a calibration method for a six-PPPS parallel manipulator which is the macro-part of a dual-drive chromosome dissection system. The calibration model is built with respect to Denavit–Hartenberg notation. Certain adjustment matrices are utilized to provide independent error parameters. The pose of the moving platform as while as relative motion of all prismatic joints and spherical joints are measured by the latest API T3 laser tracker. Other than general methods that need reconstruction of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Laser interferometer and laser tracker are used to calibrate the kinematic models of the macro parallel manipulator 33 and micro parallel manipulator. 41 Given the target pose and path point, the spatial motion trajectory of the end-effector of the 12-DOF macro-micro dual parallel manipulator is obtained according to the proposed 12-DOF smooth optimization trajectory planner. Combined with the control algorithm of the drive system, the trajectory tracking results and errors of the six servo motors and six piezoelectric actuators are shown in Figures 9 and 10.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Laser interferometer and laser tracker are used to calibrate the kinematic models of the macro parallel manipulator 33 and micro parallel manipulator. 41 Given the target pose and path point, the spatial motion trajectory of the end-effector of the 12-DOF macro-micro dual parallel manipulator is obtained according to the proposed 12-DOF smooth optimization trajectory planner. Combined with the control algorithm of the drive system, the trajectory tracking results and errors of the six servo motors and six piezoelectric actuators are shown in Figures 9 and 10.…”
Section: Resultsmentioning
confidence: 99%
“…Laser interferometer and laser tracker are used to calibrate the kinematic models of the macro parallel manipulator 33 and micro parallel manipulator. 41…”
Section: Resultsmentioning
confidence: 99%
“…A laser tracker is the typical external measuring device used in the calibration to improve the mechanism accuracy and especially suitable for a mechanism with spatially moving freedoms due to its three-dimensional (3D) tracking capability. 9,10 Researches on calibration of parallel mechanisms using laser tracker have been widely reported, 6,[10][11][12] but few are with respect to the HPMs.…”
Section: Introductionmentioning
confidence: 99%
“…In the recent years, the identification of kinematic parameter still has attracted considerable attention from numerous researchers. 7 Some particular mechanisms make the identification of kinematic parameter more difficult. The 3-PRS mechanism had an ill-conditioning problem since the shapes of its chains were approximately the same, so Huang et al.…”
Section: Introductionmentioning