1968
DOI: 10.1016/0029-554x(68)90003-7
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of an organic scintillator for neutron spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
85
0

Year Published

1977
1977
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 359 publications
(91 citation statements)
references
References 9 publications
6
85
0
Order By: Relevance
“…The latter one requires a response function to unfold the visible energies "seen" by PMTs to the recoil energy caused by incident neutrons. Such a function has been widely studied for neutron energies from a few MeV to several hundred MeV [29][30][31][32][33][34] with small scintillation detectors (several liters). Several Monte Carlo codes such as CE-CIL [29], O5S [35] and SCINFUL [36] are developed to calculate the neutron response function in liquid scintillators.…”
Section: Introductionmentioning
confidence: 99%
“…The latter one requires a response function to unfold the visible energies "seen" by PMTs to the recoil energy caused by incident neutrons. Such a function has been widely studied for neutron energies from a few MeV to several hundred MeV [29][30][31][32][33][34] with small scintillation detectors (several liters). Several Monte Carlo codes such as CE-CIL [29], O5S [35] and SCINFUL [36] are developed to calculate the neutron response function in liquid scintillators.…”
Section: Introductionmentioning
confidence: 99%
“…To correct for the energy dependent detection efficiency of the detectors and multiple scattering of neutrons on the surrounding materials the setup is modeled in GEANT4. The simulation uses the experimentally determined proton light output functions, for other recoil-particle species literature data is used [13,14]. The Monte-Carlo model has been validated against the 252 Cf(sf) PFNS [15].…”
Section: Analysis Of Pfn Datamentioning
confidence: 99%
“…The NE-213 liquid scintillator was selected because of its proven performance in other fast-neutron 2 detector assemblies. This scintillator is very efficient over the neutron energy range from 1 to above 14 MeV, does not exhibit nonisotropic behavior characteristic of stilbene [14], and is amenable to pulse-shape-discrimination [8]. Also, since the scintillator is a liquid, detectors containing NE-213 can be fabricated in various sizes and shapes to optimize performance in a specific radiation environment.…”
Section: -121mentioning
confidence: 99%
“…Black electrician's tape was wrapped around the foil and the PM tube to isolate the components from ambient light. This configuration has been shown to possess reduced response variation and improved resolution relative to detectors coated with white reflector paint and without a light pipe [8]. Visual inspection of the optical couplings was also possible since the reflector foil was added after attaching the detector to the light pipe and PM tube.…”
Section: Detector Mountingmentioning
confidence: 99%
See 1 more Smart Citation