2019
DOI: 10.1590/2317-488920192018090
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of high-temperature furnace assemblies for experiments between 200 and 600 MPa with end-loaded piston-cylinder apparatuses

Abstract: We present pressure calibration results for piston-cylinder ¾" and 1" high temperature furnace assemblies in the 200-600 MPa range aiming to expand its applicability to simulate upper crustal conditions. The furnace assemblies were made up by crushable MgO, graphite heater, pyrex glass spacer, and NaCl sleeve. Twenty-one experiments were carried out over a range of pressures (200-600 MPa) and temperatures (870-945°C) to determine the liquidus curve of NaCl. The obtained curve slope fits that given by Siewert e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…This metal capsule was inserted into a 3/4" concentric furnace assembly consisting of crushable MgO, which acts as a sample holder fixer, graphite heater, pyrex (B-silicate) glass (spacer), and NaCl sleeves to maintain the almost friction-free sample, besides steel plugs. An alumina two-bore insulator allowed thermocouple insertion and temperature measures on the capsule top-end, isolated from the thermocouple probe with a thin Al disk [56]. The 3/4" furnace assembly used in the studies can be seen in Figure 1.…”
Section: Precursor Minerals and Piston-cylinder Apparatusmentioning
confidence: 99%
“…This metal capsule was inserted into a 3/4" concentric furnace assembly consisting of crushable MgO, which acts as a sample holder fixer, graphite heater, pyrex (B-silicate) glass (spacer), and NaCl sleeves to maintain the almost friction-free sample, besides steel plugs. An alumina two-bore insulator allowed thermocouple insertion and temperature measures on the capsule top-end, isolated from the thermocouple probe with a thin Al disk [56]. The 3/4" furnace assembly used in the studies can be seen in Figure 1.…”
Section: Precursor Minerals and Piston-cylinder Apparatusmentioning
confidence: 99%
“…The capsule was loaded into a 3/4" furnace assembly that contained the reactants (starting sample) was formed concentric layers composed by crushable MgO which acts as a sample holder fixer, graphite heater, pyrex (B-silicate) glass (spacer) and NaCl sleeves to maintain the almost friction-free sample [25], besides steel plugs (Figure 2). The system assembly of the piston-cylinder apparatus complies with VLACH et al [26] procedures. An alumina two-bore insulator allows thermocouple insertion and temperature measures on the capsule top-end, isolated from the thermocouple probe with a thin Al disk.…”
Section: Sample Preparation For Piston-cylinder Apparatusmentioning
confidence: 99%