1973
DOI: 10.1049/el:19730093
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of microwave network analyser for computer-corrected S parameter measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1973
1973
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…This procedure minimizes the effects of the drawbacks mentioned previously. A general calibration procedure for microwave measurements uses a short-circuit, an open circuit and a matched load for terminations [114][115][116][117][118]. The open-circuit condition can be easily simulated; the short-circuit condition can be achieved by pressing the probe onto an aluminium foil.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This procedure minimizes the effects of the drawbacks mentioned previously. A general calibration procedure for microwave measurements uses a short-circuit, an open circuit and a matched load for terminations [114][115][116][117][118]. The open-circuit condition can be easily simulated; the short-circuit condition can be achieved by pressing the probe onto an aluminium foil.…”
Section: Discussionmentioning
confidence: 99%
“…Fourth, Teflon (ε r ≈ 2) and CCl 4 (ε r ≈ 2.1), materials with almost constant dielectric permittivity over a broad frequency range, that are also used as reference materials, have behaviours similar to that of air and hence yield a poor calibration if air is also used (especially at low frequencies). Several other calibration procedures have been suggested and tested [118], for example utilizing a short, an open into air and a short-cavity termination [123], implementing open-end measurements of the same substance with lines of different lengths [43][44][45] or the use of artificial multi-layered feed-forwards neural networks [66]. These procedures have their own inherent problems.…”
Section: Discussionmentioning
confidence: 99%
“…(1 -S22el) (1 -S11e22) -S12S21el e22 (2) and with the measured transmission coefficient of the DUT, MT2 =e30 +(1 -S22e11) (I -S11e22) -S12S21e11e22…”
Section: Introductionmentioning
confidence: 94%
“…The following six equations are used to replace level handheld programmable calculator. The first program has been fully discussed by many authors previously [2], [3], [9]; a brief discussion of this program follows.…”
Section: Introductionmentioning
confidence: 99%
“…; the actual and the measured scattering matrices. With the notation introduced in (1) the relatilon: be.tween S and S is: §-S A +BSPx(I PDX)Fc (2) where, I is the 2x2 'identity matrix. We search for a cal'ibration procedure by which the necessary informati'on for inverting (2) Using the calibration results expressed in (3) and (4) …”
Section: Calibratton With Reciprocal Elementsmentioning
confidence: 99%