2017
DOI: 10.15199/48.2017.05.15
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of the metrological characteristics of photoplethysmographic multispectral device for diagnosis the peripheral blood circulation

Abstract: This paper presents firstly-engineered photoplethysmographic multispectral device for diagnosis the peripheral blood circulation. The calculation of the main errors as: primary converter error, methodical error of measurement, setting of optical-electronic sensor error was carried out. Moreover the assessment of reliability of diagnosis the engineered device was conducted. Streszczenie. Artykuł prezentuje pierwsze rozwiązanie wielospektralnego urządzenia fotopletyzmograficzego do diagnostyki obwodowego przepły… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…As a result of segmentation, a three-dimensional model of the lungs was obtained in the STL format, shown in Figure 2, and its segmentation was carried out to eliminate visualization artifacts (Figure 2, b). Using the FreeCAD software, the bracket was modeled in real physical dimensions, which was later merged into one model with the lungs 15,16,17 . Next, the resulting model was loaded into the specialized software MeshMixer 20,21 , which allows you to perform various manipulations on the three-dimensional models before printing.…”
Section: Resultsmentioning
confidence: 99%
“…As a result of segmentation, a three-dimensional model of the lungs was obtained in the STL format, shown in Figure 2, and its segmentation was carried out to eliminate visualization artifacts (Figure 2, b). Using the FreeCAD software, the bracket was modeled in real physical dimensions, which was later merged into one model with the lungs 15,16,17 . Next, the resulting model was loaded into the specialized software MeshMixer 20,21 , which allows you to perform various manipulations on the three-dimensional models before printing.…”
Section: Resultsmentioning
confidence: 99%
“…Such approaches are also relevant in modeling the closure of cranial defects for the manufacture of a full-scale prototype of a bone implant [13][14][15] . In the tasks of configuration planning of functional rhinosurgical operations, it is also advisable to perform full-scale visualization and modeling of dynamic changes in the geometric characteristics of the anatomical structures of the operating area [16][17][18][19][20] . In addition, full-scale models can be used to predict the functional result of the operation and pre-operative verification of decisions made using tests on special aerodynamic stands [21][22][23][24] .…”
Section: Introductionmentioning
confidence: 99%