Can Corneal Biomechanical Properties Explain Difference in Tonometric Measurement in Normal Eyes?

Abstract: There was good agreement between GAT and other tonometers, but was not good enough for them to be used interchangeably. A combination of CH and CRF may better explain the variability between GAT and tonometers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 40 publications
0
3
0
Order By: Relevance
“…Over time, investigators have reported comparison studies in which TP reveal IOP greater than, equal to, and less than IOPs measured by the current gold standard GAT. [3–28]…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Over time, investigators have reported comparison studies in which TP reveal IOP greater than, equal to, and less than IOPs measured by the current gold standard GAT. [3–28]…”
Section: Introductionmentioning
confidence: 99%
“…This variability and inconsistencies in reported studies have resulted in a confused professional literature. The variability has been explained by differences in research study designs, [3] research methods applied, [4] statistical approaches used to analyze IOP measurements, [5,6] eye biomechanics, [7,8] diurnal variations of IOP, [9] body positions in which measurements were taken (sitting or supine), [10,11] age of subjects, [12–14] ethnicity of subjects, [15] central corneal thickness (CCT), [7,16–21,29] cornea shape, [22] level of training and skill of eye care professional making the measurements (ophthalmologist, technician), [23,24] subjectivity of GAT measurements, [25,26] and fundamental principles of physics underlying the differences in how IOP are measured by the TP or GAT procedure. [7,22,27,28,30]…”
Section: Introductionmentioning
confidence: 99%
“…Compared to GAT, the current gold standard, TP demonstrated varying results in different populations, with MD varying from -0.27 to 1.63 mmHg and the range of 95% LOA from 4.88 to 16.34 mmHg in normal subjects. 3,5,26,29,33,35 For glaucoma patients, especially uncontrolled individuals with elevated IOP, MD could be as high as 6.8 (range of 95% LOA = 25.9 mmHg). 25 A systematic review denoted that only 48% of the results from TP were within 2 mmHg from GAT value.…”
Section: Chapter 5 Discussionmentioning
confidence: 99%