2023
DOI: 10.1021/acs.molpharmaceut.3c00124
|View full text |Cite
|
Sign up to set email alerts
|

Can Pure Predictions of Activity Coefficients from PC-SAFT Assist Drug–Polymer Compatibility Screening?

Jáchym Pavliš,
Alex Mathers,
Michal Fulem
et al.

Abstract: The bioavailability of poorly water-soluble active pharmaceutical ingredients (APIs) can be improved via the formulation of an amorphous solid dispersion (ASD), where the API is incorporated into a suitable polymeric carrier. Optimal carriers that exhibit good compatibility (i.e., solubility and miscibility) with given APIs are typically identified through experimental means, which are routinely labor- and cost-inefficient. Therefore, the perturbed-chain statistical associating fluid theory (PC-SAFT) equation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 84 publications
0
8
0
Order By: Relevance
“…40,112 However, as will be discussed in Section 3.2.1, CS dsp FV does qualitatively predict AAPS and the overall limited compatibility of these systems. Interestingly, similar challenges regarding the numerical accuracy were recently encountered with PC-SAFT, 41 indicating that the systems of IBP with EUD and PLGA pose a broader challenge for thermodynamic models. Conversely, most other API exhibited AAD values ranging from 8% to 13%.…”
Section: Performance With Respect To Api We Further Inspect the Perfo...mentioning
confidence: 70%
See 4 more Smart Citations
“…40,112 However, as will be discussed in Section 3.2.1, CS dsp FV does qualitatively predict AAPS and the overall limited compatibility of these systems. Interestingly, similar challenges regarding the numerical accuracy were recently encountered with PC-SAFT, 41 indicating that the systems of IBP with EUD and PLGA pose a broader challenge for thermodynamic models. Conversely, most other API exhibited AAD values ranging from 8% to 13%.…”
Section: Performance With Respect To Api We Further Inspect the Perfo...mentioning
confidence: 70%
“…To contextualize these findings and the observed predictive performance, the total AAD of 14% obtained from the fully QM-aided CS dsp SG model was about 10% lower than that of other available models for ASD phase behavior. 41 It requires no experimental data for parametrization because it only relies on first-principles calculations, reflecting its practical efficacy.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations