2016
DOI: 10.1021/acs.analchem.6b02637
|View full text |Cite
|
Sign up to set email alerts
|

Cancer Diagnostics via Ultrasensitive Multiplexed Detection of Parathyroid Hormone-Related Peptides with a Microfluidic Immunoarray

Abstract: Parathyroid hormone-related peptide (PTHrP) is recognized as the major causative agent of humoral hypercalcemia of malignancy (HHM). The paraneoplastic PTHrP has also been implicated in tumor progression and metastasis of many human cancers. Conventional PTHrP detection methods like immunoradiometric assay (IRMA) lack the sensitivity required to measure target peptide levels prior to the development of hypercalcemia. In general, sensitive, multiplexed peptide measurement by immunoassay represents challenges th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
48
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 50 publications
(49 citation statements)
references
References 41 publications
0
48
0
1
Order By: Relevance
“…Array-based electrochemical systems depend on individually addressable microelectrode arrays 39 , 40 , 41 . Different biomolecules are directly immobilized on the electrodes and detected electrochemically via enzymatic reactions by potentiometry or amperometry.…”
Section: Current Multiplexing Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Array-based electrochemical systems depend on individually addressable microelectrode arrays 39 , 40 , 41 . Different biomolecules are directly immobilized on the electrodes and detected electrochemically via enzymatic reactions by potentiometry or amperometry.…”
Section: Current Multiplexing Technologiesmentioning
confidence: 99%
“…Electrochemical approaches for microfluidic multiplexing enable the realization of compact analytical devices, which combine automated assay and measurement procedures along with rapid and sensitive detection. Herein, most of the systems employ separate electrochemical measurement cells within a channel network 40 , 71 , 72 . However, the application of a single electrochemical measurement cell with one or multiple working electrodes is highly beneficial for the system design of xPOCT devices.…”
Section: Current Multiplexing Technologiesmentioning
confidence: 99%
“…Later, collaborations with Munge et al synthesized MBs with about 50,000 HRP enzymes, pushing LODs down to 1 fg mL −1 for interleukin 8 (IL-8) detection [ 94 ]. These studies were then extended for ultrasensitive single and multiplexed detection of cancer biomarker proteins on both SPEs and inkjet-printed electrodes coupled in microfluidic devices [ 31 , 95 , 96 , 97 , 98 , 99 , 100 , 101 , 102 , 103 ] ( Figure 6 ).…”
Section: Immunoassay Techniques For Printed Electrodesmentioning
confidence: 99%
“…Otieno et al then modified this microfluidic device with an online protein capture chamber, where the analytes are separated from the serum in an isolated compartment with Mb-Ab 2 , before being introduced into the detection channel with the electrodes [ 99 ]. Otieno et al further detected parathyroid hormone-related peptide (PTHrP) fragments which act as biomarkers for bone metastasis of breast and prostate cancer obtaining LODs of 3 fg mL −1 ,1000-fold less than the traditionally used immunoradiometric assay (IRMA) [ 100 ].…”
Section: Immunoassay Techniques For Printed Electrodesmentioning
confidence: 99%
See 1 more Smart Citation