2006
DOI: 10.1039/b514007b
|View full text |Cite
|
Sign up to set email alerts
|

Capabilities of laser ablation—inductively coupled plasma mass spectrometry for (trace) element analysis of car paints for forensic purposes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0
2

Year Published

2007
2007
2020
2020

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 52 publications
(42 citation statements)
references
References 28 publications
0
40
0
2
Order By: Relevance
“…36 In particular, the flat-top beam profile of the 193 nm ArF excimer laser used in this work is ideal for this kind of application, as documented in previous works. [37][38][39] In principle, by using an output energy significantly exceeding the threshold and a sufficiently wide laser beam diameter, it is possible to obtain representative compositional data throughout the process of ablation, as long as a value of 6 for the depth/ diameter ratio is not exceeded, 34 although for this particular laser system it has been recommended not to exceed a depth/diameter ratio of 1.5, in order to achieve uniform flat-bottomed craters. 40 The examination of the craters obtained after ablation of the samples by SEM permitted us to estimate that the penetration depth obtained after firing 600 pulses varied between 21 and 27 µm, corresponding to approximately 40 nm of penetration per pulse.…”
Section: Resultsmentioning
confidence: 99%
“…36 In particular, the flat-top beam profile of the 193 nm ArF excimer laser used in this work is ideal for this kind of application, as documented in previous works. [37][38][39] In principle, by using an output energy significantly exceeding the threshold and a sufficiently wide laser beam diameter, it is possible to obtain representative compositional data throughout the process of ablation, as long as a value of 6 for the depth/ diameter ratio is not exceeded, 34 although for this particular laser system it has been recommended not to exceed a depth/diameter ratio of 1.5, in order to achieve uniform flat-bottomed craters. 40 The examination of the craters obtained after ablation of the samples by SEM permitted us to estimate that the penetration depth obtained after firing 600 pulses varied between 21 and 27 µm, corresponding to approximately 40 nm of penetration per pulse.…”
Section: Resultsmentioning
confidence: 99%
“…7 However, in LA-ICP-MS, high mass resolution MS was needed to eliminate the polyatomic spectroscopic interferences that originated from the complex matrix of car paints, which would have otherwise masked the analyte signal profile, thereby degrading the discriminating power of the technique. 4 This problem arises because, in ICP-MS, each analyte possesses only one or a few isotopes, which is in contrast to ICP-OES, where a large number of emission lines are usually available for each analyte, enabling the selection of one or more interference-free emission lines in each case.…”
Section: Introductionmentioning
confidence: 99%
“…Fast transient multielement analysis is performed at a fixed resolution mode setting. Deconinck et al 114 used laser ablation with quadrupole-based ICP-MS and ICP-SFMS for element analysis of car paint fragments found at crime scenes for forensic purposes. It was observed that the complex matrix composition of some of the layers -organic components, kaolin, talc, barite and/or Fe-containing pigments -resulted in spectral interferences, significantly affecting the signal profiles, especially for the transition metals when using the quadrupole-based instrument.…”
Section: Ceramics Glass and Paintsmentioning
confidence: 99%