2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies 2008
DOI: 10.1109/drpt.2008.4523872
|View full text |Cite
|
Sign up to set email alerts
|

Capacity credit evaluation: A literature review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 21 publications
1
9
0
Order By: Relevance
“…The capacity values are given as a percentage of the 1,080 MW-e nameplate generating capacity of the deployments. The figure shows that CSP plants tend to have higher capacity values than wind generators, which is consistent with previous findings [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37]. This is both because of the coincidence between solar resource availability and peak loads, as well as the dispatchability of CSP with TES.…”
Section: Revenue Estimatessupporting
confidence: 81%
See 1 more Smart Citation
“…The capacity values are given as a percentage of the 1,080 MW-e nameplate generating capacity of the deployments. The figure shows that CSP plants tend to have higher capacity values than wind generators, which is consistent with previous findings [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37]. This is both because of the coincidence between solar resource availability and peak loads, as well as the dispatchability of CSP with TES.…”
Section: Revenue Estimatessupporting
confidence: 81%
“…A number of different capacity value estimation techniques have been applied to wind [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] and CSP [37]. These include reliability theory-based methods and capacity factor-based approximations.…”
Section: Revenue Estimatesmentioning
confidence: 99%
“…The steps used to calculate the ELCC of a CSP generator 2 1. For a given set of conventional generators, the LOLE of the system without the CSP plant is calculated using the following formula:…”
Section: Effective Load Carrying Capabilitymentioning
confidence: 99%
“…The CSP plant is added to the system and the LOLE is recalculated. This is shown in (2) as LOLE CSP , where C i is the output of the CSP plant in hour i. Since the CSP plant has been added to the system, LOLE CSP will be lower than LOLE (indicating a more reliable system with lower LOLPs).…”
Section: Effective Load Carrying Capabilitymentioning
confidence: 99%
“…According to the North American Electric Reliability Corporation (NERC), quantifying the contribution of renewable energy resources to resource adequacy of bulk power systems is a very important and emerging issue [1]. Therefore, assessing the adequacy of renewable generation technologies and consequently estimating their capacity value is crucial for accurate reliability and planning of power systems [2]. Previous analyses have considered the capacity value of wind [1,[3][4][5][6][7][8], photovoltaic (PV) solar [9][10][11][12][13][14], and concentrating solar power (CSP) plants [15].…”
Section: Introductionmentioning
confidence: 99%