1982
DOI: 10.1021/ac00241a028
|View full text |Cite
|
Sign up to set email alerts
|

Capillary gas chromatography/atmospheric pressure negative chemical ionization mass spectrometry of the 22 isomeric tetrachlorodibenzo-p-dioxins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
31
0

Year Published

1982
1982
2009
2009

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 60 publications
(33 citation statements)
references
References 54 publications
2
31
0
Order By: Relevance
“…This statement is based on both methods ionizing compounds by the mechanisms of EC, dissociative EC, proton abstraction, and halide adduction, and led to the conclusion that these techniques ionize a wider array of compounds than Ni-APCI. However, several studies of Ni-APCI have shown this method to have excellent sensitivity, especially for compounds with positive electron affinity (EA) [5,12,13]. Early work with APCI was primarily carried out using gas chromatographic introduction and, thus, the ion source was solvent free [13][14][15][16][17].…”
Section: Resultsmentioning
confidence: 99%
“…This statement is based on both methods ionizing compounds by the mechanisms of EC, dissociative EC, proton abstraction, and halide adduction, and led to the conclusion that these techniques ionize a wider array of compounds than Ni-APCI. However, several studies of Ni-APCI have shown this method to have excellent sensitivity, especially for compounds with positive electron affinity (EA) [5,12,13]. Early work with APCI was primarily carried out using gas chromatographic introduction and, thus, the ion source was solvent free [13][14][15][16][17].…”
Section: Resultsmentioning
confidence: 99%
“…The detection limits for 2,3,7,8-TCDD/F in the SIM mode were 0.5 pg for the 2,3,7,8-TCDF standard (Clement & Tosine, 1988) and 14-40 pg in deionized water . PCBs, chlorinated methoxybiphenyls, and some organochlorine pesticides did not interfere; therefore that method had an important advantage (Mitchum et al, 1982). According to a study (Revelsky et al, 1992), the detection limit of 2,3,7,8-TCDD in aqueous samples in the SIM mode (m/z 176) was 10 pg.…”
Section: B Sensitive Detection: Negative Chemical Ionization With DImentioning
confidence: 99%
“…It was stated (Mitchum et al, 1982) that for all 2:2-substituted TCDDs, excluding 1,3,7,8-and 2,3,7,8-, and for all 1:3-substituted TCDDs, excluding 1,2,4,6-and 1,2,4,9-, the formation of the M À ion is characteristic for the APCI mode with oxygen as reagent gas. In the TCDF spectra, Cl À and [M-Cl þ O] À were the major ion peaks, and the molecular ions were not observed under APCI conditions (Clement & Tosine, 1988).…”
Section: B Sensitive Detection: Negative Chemical Ionization With DImentioning
confidence: 99%
“…Recently, several other modes of mass spectrometry involving chemical ionization with reagent gases such as methane, oxygen-doped methane, and isobutane have been used to improve sensitivity and in some cases isomer specificity (25)(26)(27).…”
Section: Conjrmatory Techiziques Usiizg Gclinsmentioning
confidence: 99%